Data coverage & sources
The stored record for ALMiG COMBI XP 4: specifications, configurations, documents, sources, and gaps.
One model, connected records
ALMiG → ALMiG Screw Compressor COMBI XP → COMBI XP 4
Manufacturer model: COMBI XP 4 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
8 stored observations · 2 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Needs review · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0,20 - 0,59 m³/min | 12 m3/h | Frequency not stated · range at 8 bar; rate according to ISO 1217 (Annex C-2009) free air delivery | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,20 - 0,59Retrieved 2026-10-05 |
| 0,18 - 0,53 m³/min | 10.8 m3/h | Frequency not stated · range at 10 bar; rate according to ISO 1217 (Annex C-2009) free air delivery | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,18 - 0,53Retrieved 2026-10-05 |
| 0,17 - 0,41 m³/min | 10.2 m3/h | Frequency not stated · range at 13 bar; rate according to ISO 1217 (Annex C-2009) free air delivery | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,17 - 0,41Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4 kW | 4 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMotor rated power: 4Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 465 kg | 465 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 465Retrieved 2026-10-05 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Needs review · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 10 bar | 10000 mbar | Frequency not stated · range the pressure "Volume flow rate according to ISO 1217 (Annex C-2009)" is stated at (at 10 bar; rate according to ISO 1217 (Annex C-2009)) unspecified | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,18 - 0,53Retrieved 2026-10-20 |
| 13 bar | 13000 mbar | Frequency not stated · range the pressure "Volume flow rate according to ISO 1217 (Annex C-2009)" is stated at (at 13 bar; rate according to ISO 1217 (Annex C-2009)) unspecified | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,17 - 0,41Retrieved 2026-10-20 |
| 8 bar | 8000 mbar | Frequency not stated · range the pressure "Volume flow rate according to ISO 1217 (Annex C-2009)" is stated at (at 8 bar; rate according to ISO 1217 (Annex C-2009)) unspecified | Source · OEM_SOURCE not a model rating Volume flow rate according to ISO 1217 (Annex C-2009): 0,20 - 0,59Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 1 | 0 |
|