Data coverage & sources
The stored record for ALMiG SIMPLEXX SC 132: specifications, configurations, documents, sources, and gaps.
One model, connected records
ALMiG → ALMiG Screw compressor SIMPLEXX → SIMPLEXX SC 132
Manufacturer model: SIMPLEXX SC 132 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Oil-Free Screw / Rotary Screw
Related applications: Food-Contact Air, Instrument Air, Medical Air, Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, Electronics, Food + Beverage, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Pharmaceutical, Plastics, Power Generation, Printing, Pulp + Paper, Semiconductor, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
10 stored observations · 0 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Other conditions · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 24.0 m³/min | 1440 m3/h | 50 Hz · model 50 Hz wir air cooling; according to ISO 1217 (Annex C-2009), max. free air delivery | Source · OEM_SOURCE different frequency Volume flow according to ISO 1217 (Annex C-2009), max.: 24.0Retrieved 2026-10-05 |
| 10.4 m³/min | 624 m3/h | 50 Hz · model 50 Hz wir air cooling; according to ISO 1217 (Annex C-2009), min. free air delivery | Source · OEM_SOURCE different frequency Volume flow according to ISO 1217 (Annex C-2009), min.: 10.4Retrieved 2026-10-05 |
| 24.9 m³/min | 1494 m3/h | 50 Hz · model 50 Hz with water cooling; according to ISO 1217 (Annex C-2009), max. free air delivery | Source · OEM_SOURCE different frequency Volume flow according to ISO 1217 (Annex C-2009), max.: 24.9Retrieved 2026-10-05 |
| 11.0 m³/min | 660 m3/h | 50 Hz · model 50 Hz with water cooling; according to ISO 1217 (Annex C-2009), min. free air delivery | Source · OEM_SOURCE different frequency Volume flow according to ISO 1217 (Annex C-2009), min.: 11.0Retrieved 2026-10-05 |
Max. pressure · Needs review · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4 - 8.6 bar | 4000 mbar | 50 Hz · range 50 Hz wir air cooling unspecified | Source · OEM_SOURCE not a model rating, different frequency Operating pressure: 4 - 8.6Retrieved 2026-10-05 |
| 4 - 10.4 bar | 4000 mbar | 50 Hz · range 50 Hz with water cooling unspecified | Source · OEM_SOURCE not a model rating, different frequency Operating pressure: 4 - 10.4Retrieved 2026-10-05 |
Motor power · Other conditions · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 132 kW | 132 kW | 50 Hz · model 50 Hz wir air cooling unspecified | Source · OEM_SOURCE different frequency Rated motor power: 132Retrieved 2026-10-05 |
| 132 kW | 132 kW | 50 Hz · model 50 Hz with water cooling unspecified | Source · OEM_SOURCE different frequency Rated motor power: 132Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Other conditions · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4300 kg | 4300 kg | 50 Hz · model 50 Hz wir air cooling unspecified | Source · OEM_SOURCE different frequency Weight: 4300Retrieved 2026-10-05 |
| 3700 kg | 3700 kg | 50 Hz · model 50 Hz with water cooling unspecified | Source · OEM_SOURCE different frequency Weight: 3700Retrieved 2026-10-05 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|