Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for ALMiG SIMPLEXX SC 250: specifications, configurations, documents, sources, and gaps.

One model, connected records

ALMiG → ALMiG Screw compressor SIMPLEXX → SIMPLEXX SC 250

Manufacturer model: SIMPLEXX SC 250 · OEM article / order number: Not collected · Equipment type: compressor

Technology: Oil-Free Screw / Rotary Screw

Related applications: Food-Contact Air, Instrument Air, Medical Air, Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, Electronics, Food + Beverage, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Pharmaceutical, Plastics, Power Generation, Printing, Pulp + Paper, Semiconductor, Water + Wastewater, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

10 stored observations · 0 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Other conditions · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
44.4 m³/min2664 m3/h50 Hz · model
50 Hz wir air cooling; according to ISO 1217 (Annex C-2009), max.
free air delivery
Source · OEM_SOURCE
different frequency
Volume flow according to ISO 1217 (Annex C-2009), max.: 44.4
Retrieved 2026-10-05
15.4 m³/min924 m3/h50 Hz · model
50 Hz wir air cooling; according to ISO 1217 (Annex C-2009), min.
free air delivery
Source · OEM_SOURCE
different frequency
Volume flow according to ISO 1217 (Annex C-2009), min.: 15.4
Retrieved 2026-10-05
45.4 m³/min2724 m3/h50 Hz · model
50 Hz with water cooling; according to ISO 1217 (Annex C-2009), max.
free air delivery
Source · OEM_SOURCE
different frequency
Volume flow according to ISO 1217 (Annex C-2009), max.: 45.4
Retrieved 2026-10-05
15.4 m³/min924 m3/h50 Hz · model
50 Hz with water cooling; according to ISO 1217 (Annex C-2009), min.
free air delivery
Source · OEM_SOURCE
different frequency
Volume flow according to ISO 1217 (Annex C-2009), min.: 15.4
Retrieved 2026-10-05
Max. pressure · Needs review · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4 - 8.6 bar4000 mbar50 Hz · range
50 Hz wir air cooling
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Operating pressure: 4 - 8.6
Retrieved 2026-10-05
4 - 10.4 bar4000 mbar50 Hz · range
50 Hz with water cooling
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Operating pressure: 4 - 10.4
Retrieved 2026-10-05
Motor power · Other conditions · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 kW250 kW50 Hz · model
50 Hz wir air cooling
unspecified
Source · OEM_SOURCE
different frequency
Rated motor power: 250
Retrieved 2026-10-05
250 kW250 kW50 Hz · model
50 Hz with water cooling
unspecified
Source · OEM_SOURCE
different frequency
Rated motor power: 250
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Other conditions · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5600 kg5600 kg50 Hz · model
50 Hz wir air cooling
unspecified
Source · OEM_SOURCE
different frequency
Weight: 5600
Retrieved 2026-10-05
5350 kg5350 kg50 Hz · model
50 Hz with water cooling
unspecified
Source · OEM_SOURCE
different frequency
Weight: 5350
Retrieved 2026-10-05
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected