Data coverage & sources
The stored record for Anest Iwata SLP-151EFD: specifications, configurations, documents, sources, and gaps.
One model, connected records
Anest Iwata → Anest Iwata スクロールコンプレッサ SLP Eシリーズ → SLP-151EFD
Manufacturer model: SLP-151EFD · OEM article / order number: Not collected · Equipment type: compressor
Technology: Scroll
Related applications: Food-Contact Air, Medical Air
Related industries: Electronics, Medical
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
3 stored observations · 3 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 130 L/min | 7.8 m3/h | Frequency not stated · model 50 / 60 Hz free air delivery | Source · OEM_SOURCE吐出空気量: 130Retrieved 2026-10-05 |
Max. pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.00 MPa | 10000 mbar | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCE制御圧力 上限: 1.00Retrieved 2026-10-05 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.5 kW | 1.5 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCE【電動機】出力: 1.5Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 38 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |