Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for ANLET BWH12511: specifications, configurations, documents, sources, and gaps.

One model, connected records

ANLET → ANLET BWH / BWN submersible roots blowers → BWH12511

Manufacturer model: BWH12511 · OEM article / order number: Not collected · Equipment type: blower

Technology: Blowers

Related applications: Aeration, Pneumatic Conveying, Pressure Conveying
Related industries: Mining, Pulp + Paper, Water + Wastewater

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

20 stored observations · 9 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Blower flow · Sourced · 9 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9.6 m³/min576 m3/h50 Hz · model
50 Hz; at 10 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
different frequency
Air flow: 9.6
Retrieved 2026-10-06
9.3 m³/min558 m3/h50 Hz · model
50 Hz; at 20 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
different frequency
Air flow: 9.3
Retrieved 2026-10-06
9.0 m³/min540 m3/h50 Hz · model
50 Hz; at 30 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
different frequency
Air flow: 9.0
Retrieved 2026-10-06
8.8 m³/min528 m3/h50 Hz · model
50 Hz; at 40 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
different frequency
Air flow: 8.8
Retrieved 2026-10-06
8.6 m³/min516 m3/h50 Hz · model
50 Hz; at 50 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
different frequency
Air flow: 8.6
Retrieved 2026-10-06
11.4 m³/min684 m3/h60 Hz · model
60 Hz; at 10 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
Air flow: 11.4
Retrieved 2026-10-06
11.1 m³/min666 m3/h60 Hz · model
60 Hz; at 20 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
Air flow: 11.1
Retrieved 2026-10-06
10.8 m³/min648 m3/h60 Hz · model
60 Hz; at 30 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
Air flow: 10.8
Retrieved 2026-10-06
10.5 m³/min630 m3/h60 Hz · model
60 Hz; at 40 kPa discharge pressure; 標準吸込状態空気量 (standard suction conditions)
unspecified
Source · OEM_SOURCE
Air flow: 10.5
Retrieved 2026-10-06
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. vacuum · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11 kW11 kW50 Hz · model
50 Hz; 水中モータ (submersible motor) 3相200V×4P
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 11
Retrieved 2026-10-06
11 kW11 kW60 Hz · model
60 Hz; 水中モータ (submersible motor) 3相200V×4P
unspecified
Source · OEM_SOURCE
Motor power: 11
Retrieved 2026-10-06
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Power consumption · Sourced · 9 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3.7 kW3.7 kW50 Hz · model
50 Hz; at 10 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
different frequency
Power consumption: 3.7
Retrieved 2026-10-06
5.5 kW5.5 kW50 Hz · model
50 Hz; at 20 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
different frequency
Power consumption: 5.5
Retrieved 2026-10-06
7.3 kW7.3 kW50 Hz · model
50 Hz; at 30 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
different frequency
Power consumption: 7.3
Retrieved 2026-10-06
9.2 kW9.2 kW50 Hz · model
50 Hz; at 40 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
different frequency
Power consumption: 9.2
Retrieved 2026-10-06
11.0 kW11 kW50 Hz · model
50 Hz; at 50 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
different frequency
Power consumption: 11.0
Retrieved 2026-10-06
4.4 kW4.4 kW60 Hz · model
60 Hz; at 10 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
Power consumption: 4.4
Retrieved 2026-10-06
6.6 kW6.6 kW60 Hz · model
60 Hz; at 20 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
Power consumption: 6.6
Retrieved 2026-10-06
8.8 kW8.8 kW60 Hz · model
60 Hz; at 30 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
Power consumption: 8.8
Retrieved 2026-10-06
11.0 kW11 kW60 Hz · model
60 Hz; at 40 kPa discharge pressure; 所要動力 (power required)
unspecified
Source · OEM_SOURCE
Power consumption: 11.0
Retrieved 2026-10-06

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected