Data coverage & sources
The stored record for Atlas Copco GA 55: specifications, configurations, documents, sources, and gaps.
One model, connected records
Atlas Copco → Atlas Copco GA data (GA30-90_GA37_110VSD_EN) → GA 55
Manufacturer model: GA 55 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
32 stored observations · 16 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 643 m³/hr | 643 m3/h | 50 Hz · model 7.5 bar(e) version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 643Retrieved 2026-10-03 |
| 614 m³/hr | 614 m3/h | 50 Hz · model 8.5 bar(e) version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 614Retrieved 2026-10-03 |
| 546 m³/hr | 546 m3/h | 50 Hz · model 10 bar(e) version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 546Retrieved 2026-10-03 |
| 488 m³/hr | 488 m3/h | 50 Hz · model 13 bar(e) version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 488Retrieved 2026-10-03 |
| 654 m³/hr | 654 m3/h | 60 Hz · model 7.4 bar(e) version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 654Retrieved 2026-10-03 |
| 601 m³/hr | 601 m3/h | 60 Hz · model 9.1 bar(e) version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 601Retrieved 2026-10-03 |
| 562 m³/hr | 562 m3/h | 60 Hz · model 10.8 bar(e) version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 562Retrieved 2026-10-03 |
| 516 m³/hr | 516 m3/h | 60 Hz · model 12.5 bar(e) version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 516Retrieved 2026-10-03 |
Max. pressure · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 7.5 bar(e) | — | 50 Hz · model 7.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 7.5Retrieved 2026-10-03 |
| 8.5 bar(e) | — | 50 Hz · model 8.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 8.5Retrieved 2026-10-03 |
| 10 bar(e) | — | 50 Hz · model 10 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 10Retrieved 2026-10-03 |
| 13 bar(e) | — | 50 Hz · model 13 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 13Retrieved 2026-10-03 |
| 7.4 bar(e) | — | 60 Hz · model 7.4 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 7.4Retrieved 2026-10-03 |
| 9.1 bar(e) | — | 60 Hz · model 9.1 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 9.1Retrieved 2026-10-03 |
| 10.8 bar(e) | — | 60 Hz · model 10.8 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 10.8Retrieved 2026-10-03 |
| 12.5 bar(e) | — | 60 Hz · model 12.5 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 12.5Retrieved 2026-10-03 |
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 55 kW | 55 kW | 50 Hz · model 7.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Installed motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 50 Hz · model 8.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Installed motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 50 Hz · model 10 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Installed motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 50 Hz · model 13 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Installed motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 60 Hz · model 7.4 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEInstalled motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 60 Hz · model 9.1 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEInstalled motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 60 Hz · model 10.8 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEInstalled motor power: 55Retrieved 2026-10-03 |
| 55 kW | 55 kW | 60 Hz · model 12.5 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCEInstalled motor power: 55Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 71 dB(A) | 71 dB(A) | 50 Hz · model 7.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Noise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 50 Hz · model 8.5 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Noise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 50 Hz · model 10 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Noise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 50 Hz · model 13 bar(e) version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Noise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 60 Hz · model 7.4 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCENoise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 60 Hz · model 9.1 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCENoise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 60 Hz · model 10.8 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCENoise level: 71Retrieved 2026-10-03 |
| 71 dB(A) | 71 dB(A) | 60 Hz · model 12.5 bar(e) version, 60 Hz unspecified | Source · OEM_SOURCENoise level: 71Retrieved 2026-10-03 |
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |