Specifications and evidence

17 stored observations · 0 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Other conditions · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5200 l/min312 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 2 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 5200
Retrieved 2026-10-03
312 m³/h312 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 2 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 312
Retrieved 2026-10-03
7000 l/min420 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 3 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 7000
Retrieved 2026-10-03
420 m³/h420 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 3 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 420
Retrieved 2026-10-03
8700 l/min522 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 8700
Retrieved 2026-10-03
522 m³/h522 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 522
Retrieved 2026-10-03
9600 l/min576 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 9600
Retrieved 2026-10-03
576 m³/h576 m3/h50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 576
Retrieved 2026-10-03
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Other conditions · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
132 kW132 kW50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 2 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 132
Retrieved 2026-10-03
132 kW132 kW50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 3 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 132
Retrieved 2026-10-03
132 kW132 kW50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 132
Retrieved 2026-10-03
160 kW160 kW50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 160
Retrieved 2026-10-03
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Other conditions · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3350 kg3350 kg50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 2 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 3350
Retrieved 2026-10-03
3350 kg3350 kg50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 3 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 3350
Retrieved 2026-10-03
3350 kg3350 kg50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 3350
Retrieved 2026-10-03
3420 kg3420 kg50 Hz · model
GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 3420
Retrieved 2026-10-03
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Other conditions · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
90 to 365 bar90000 mbar50 Hz · model
the pressure "Capacity (Effective free air delivery)" is stated at (GIB 26 series, 90 to 365 bar | 50 Hz, Inlet pressure: 2 bar; (Effective free air delivery))
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 5200
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected