Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Becker DVT 3.100: specifications, configurations, documents, sources, and gaps.

One model, connected records

Becker → DVT series → DVT 3.100

Manufacturer model: DVT 3.100 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Rotary Vane

Related applications: CNC Routing, Material Handling, Pick + Place, Vacuum Hold-Down
Related industries: Electronics, General Manufacturing, Printing, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

7 stored observations · 3 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
103 m³/h103 m3/h50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
ower 60 Hz: | 4.5…4.8 kW Noise Level 60 Hz: | 76…77 dB(A) Weight: | 49 kg without motor DVT 3.100 | 103/120 m³/h | ±0.5/±0.5 bar | 5.5/6.6 kW Volume flow 50 Hz: | 103 m³/h Pressure/Vacuum relative 50 Hz:
Retrieved 2026-10-20
120 m³/h120 m3/h60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
60 Hz: | 4.5…4.8 kW Noise Level 60 Hz: | 76…77 dB(A) Weight: | 49 kg without motor DVT 3.100 | 103/120 m³/h | ±0.5/±0.5 bar | 5.5/6.6 kW Volume flow 50 Hz: | 103 m³/h Pressure/Vacuum relative 50 Hz: | ±
Retrieved 2026-10-20
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.5 kW5.5 kW50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Level 60 Hz: | 76…77 dB(A) Weight: | 49 kg without motor DVT 3.100 | 103/120 m³/h | ±0.5/±0.5 bar | 5.5/6.6 kW Volume flow 50 Hz: | 103 m³/h Pressure/Vacuum relative 50 Hz: | ±0.5 bar Power 50 Hz: | 5.5
Retrieved 2026-10-20
6.6 kW6.6 kW60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
l 60 Hz: | 76…77 dB(A) Weight: | 49 kg without motor DVT 3.100 | 103/120 m³/h | ±0.5/±0.5 bar | 5.5/6.6 kW Volume flow 50 Hz: | 103 m³/h Pressure/Vacuum relative 50 Hz: | ±0.5 bar Power 50 Hz: | 5.5 kW N
Retrieved 2026-10-20
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
71 kg71 kgFrequency not stated · model
without motor
unspecified
Source · OEM_SOURCE
/Vacuum relative 60 Hz: | ±0.5 bar Power 60 Hz: | 6.6 kW Noise Level 60 Hz: | 77…78 dB(A) Weight: | 71 kg without motor DVT 3.100 | 103/120 m³/h | ±0.6/±0.6 bar | 5.5/6.6 kW Volume flow 50 Hz: | 103 m³/
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. vacuum · Other conditions · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
±0.6 bar— 50 Hz · model
as printed: "Pressure/Vacuum relative 50 Hz:"
unspecified
Source · OEM_SOURCE
different frequency
Pressure/Vacuum relative 50 Hz: | ±0.6 bar
Retrieved 2026-10-20
±0.5 bar— 50 Hz · model
as printed: "Pressure/Vacuum relative 50 Hz:"
unspecified
Source · OEM_SOURCE
different frequency
Pressure/Vacuum relative 50 Hz: | ±0.5 bar
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected