Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch COBRA DH 4560 A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → COBRA DH 2760–6260 A → COBRA DH 4560 A

Manufacturer model: COBRA DH 4560 A · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

44 stored observations · 24 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3077 m³/h m³/h3077 m3/h50 Hz · model
ISO 50 Hz; at 1 hPa(mbar)
unspecified
Source · OEM_VERIFIED
different frequency
Pumping speed at 1 hPa(mbar): 3077 m³/h
Retrieved 2026-10-01
3077 m³/h m³/h3077 m3/h60 Hz · model
ISO 60 Hz; at 1 hPa(mbar)
unspecified
Source · OEM_VERIFIED
Pumping speed at 1 hPa(mbar): 3077 m³/h
Retrieved 2026-10-01
2066.8 ACFM ACFM3511.514 m3/h60 Hz · model
US 60 Hz; at 0.75 TORR
actual inlet
Source · OEM_SOURCE
Pumping speed at 0.75 TORR: 2066.8 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.001 hPa (mbar) hPa (mbar)0.001 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: 0.001 hPa (mbar)
Retrieved 2026-10-01
0.001 hPa (mbar) hPa (mbar)0.001 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: 0.001 hPa (mbar)
Retrieved 2026-10-01
0.00075 Torr Torr0.001 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Ultimate pressure: 0.00075 Torr
Retrieved 2026-10-01
Motor power · Sourced · 7 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
22.5 kW kW22.5 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 22.5 kW
Retrieved 2026-10-01
15.0 kW kW15 kW50 Hz · model
ISO 50 Hz; backing pump
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating backing pump: 15.0 kW
Retrieved 2026-10-01
11.0 kW kW11 kW50 Hz · model
ISO 50 Hz; vacuum booster
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating vacuum booster: 11.0 kW
Retrieved 2026-10-01
22.5 kW kW22.5 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 22.5 kW
Retrieved 2026-10-01
15.0 kW kW15 kW60 Hz · model
ISO 60 Hz; backing pump
unspecified
Source · OEM_SOURCE
Nominal motor rating backing pump: 15.0 kW
Retrieved 2026-10-01
11.0 kW kW11 kW60 Hz · model
ISO 60 Hz; vacuum booster
unspecified
Source · OEM_SOURCE
Nominal motor rating vacuum booster: 11.0 kW
Retrieved 2026-10-01
30 hp hp22.371 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 30 hp
Retrieved 2026-10-01
Speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3600 min⁻¹ min⁻¹3600 rpm50 Hz · model
ISO 50 Hz; backing pump
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed backing pump: 3600 min⁻¹
Retrieved 2026-10-01
7500 min⁻¹ min⁻¹7500 rpm50 Hz · model
ISO 50 Hz; vacuum booster
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed vacuum booster: 7500 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz; backing pump
unspecified
Source · OEM_SOURCE
Nominal motor speed backing pump: 3600 min⁻¹
Retrieved 2026-10-01
7500 min⁻¹ min⁻¹7500 rpm60 Hz · model
ISO 60 Hz; vacuum booster
unspecified
Source · OEM_SOURCE
Nominal motor speed vacuum booster: 7500 min⁻¹
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
69 dB(A) dB(A)69 dB(A)50 Hz · model
ISO 50 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (ISO 2151), KpA = 3 dB: 69 dB(A)
Retrieved 2026-10-01
69 dB(A) dB(A)69 dB(A)60 Hz · model
ISO 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 2151), KpA = 3 dB: 69 dB(A)
Retrieved 2026-10-01
69 dB(A) dB(A)69 dB(A)60 Hz · model
US 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 2151), KpA = 3 dB: 69 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
950 kg kg950 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 950 kg
Retrieved 2026-10-01
950 kg kg950 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 950 kg
Retrieved 2026-10-01
2090 Lbs. Lbs.948.0073 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_SOURCE
Weight approx.: 2090 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1446 x 630 x 1140 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1446 x 630 x 1140 mm
Retrieved 2026-10-01
1446 x 630 x 1140 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1446 x 630 x 1140 mm
Retrieved 2026-10-01
56.9 x 24.8 x 44.9 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 56.9 x 24.8 x 44.9 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO-F | DN 150 PN16 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 160 ISO-F | DN 150 PN16
Retrieved 2026-10-01
DN 160 ISO-F | DN 150 PN16 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO-F | DN 150 PN16
Retrieved 2026-10-01
DN 160 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO-F
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 63 ISO-F — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 63 ISO-F
Retrieved 2026-10-01
DN 63 ISO-F — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 63 ISO-F
Retrieved 2026-10-01
DN 63 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 63 ISO-F
Retrieved 2026-10-01
Leakage Rate · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1 · 10⁻⁶ Pa m³/s · 10⁻⁶ Pa m³/s— 60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: 1 · 10⁻⁶ Pa m³/s
Retrieved 2026-10-01
Power consumption · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9.5 kW kW9.5 kW50 Hz · model
ISO 50 Hz; at ultimate pressure
unspecified
Source · OEM_SOURCE
different frequency
Power consumption at ultimate pressure: 9.5 kW
Retrieved 2026-10-01
4.6 kW kW4.6 kW50 Hz · model
ISO 50 Hz; idle mode
unspecified
Source · OEM_SOURCE
different frequency
Power consumption idle mode: 4.6 kW
Retrieved 2026-10-01
9.5 kW kW9.5 kW60 Hz · model
ISO 60 Hz; at ultimate pressure
unspecified
Source · OEM_SOURCE
Power consumption at ultimate pressure: 9.5 kW
Retrieved 2026-10-01
4.6 kW kW4.6 kW60 Hz · model
ISO 60 Hz; idle mode
unspecified
Source · OEM_SOURCE
Power consumption idle mode: 4.6 kW
Retrieved 2026-10-01
12.3 hp hp9.1721 kW60 Hz · model
US 60 Hz; at ultimate pressure
unspecified
Source · OEM_SOURCE
Power consumption at ultimate pressure: 12.3 hp
Retrieved 2026-10-01
4.6 hp hp3.4302 kW60 Hz · model
US 60 Hz; at ultimate pressure with energy saving module
unspecified
Source · OEM_SOURCE
Power consumption at ultimate pressure with energy saving module: 4.6 hp
Retrieved 2026-10-01
Protection Class · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
IP54 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Protection class: IP54
Retrieved 2026-10-01
IP54 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Protection class: IP54
Retrieved 2026-10-01
Water Consumption · Needs review · 3 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
10 l/min l/min0.6 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Water consumption: 10 l/min
Retrieved 2026-10-01
10 l/min l/min0.6 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Water consumption: 10 l/min
Retrieved 2026-10-01
14 l/min l/min0.84 m3/h60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Water consumption: 14 l/min
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected