Data coverage & sources
The stored record for Busch COBRA DX 0650 A PLUS: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → COBRA DX 0650/0950 A PLUS → COBRA DX 0650 A PLUS
Manufacturer model: COBRA DX 0650 A PLUS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| max. 650 m³/h m³/h | 650 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: max. 650 m³/hRetrieved 2026-10-01 |
| max. 650 m³/h m³/h | 650 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: max. 650 m³/hRetrieved 2026-10-01 |
| 382.5 ACFM ACFM | 649.8713 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 382.5 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 0.1 hPa (mbar) hPa (mbar) | 0.1 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: ≤ 0.1 hPa (mbar)Retrieved 2026-10-01 |
| ≤ 0.1 hPa (mbar) hPa (mbar) | 0.1 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 0.1 hPa (mbar)Retrieved 2026-10-01 |
| 0.075 Torr Torr | 0.1 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 0.075 TorrRetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15 kW kW | 15 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 15 kWRetrieved 2026-10-01 |
| 15 kW kW | 15 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 15 kWRetrieved 2026-10-01 |
| 20 hp hp | 14.914 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 20 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3000 rpm rpm | 3000 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3000 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 67 dB(A) dB(A) | 67 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIED different frequency Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)Retrieved 2026-10-01 |
| ≤ 67 dB(A) dB(A) | 67 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)Retrieved 2026-10-01 |
| ≤ 67 dB(A) dB(A) | 67 dB(A) | 60 Hz · model US 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1125 kg kg | 1125 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 1125 kgRetrieved 2026-10-01 |
| 1125 kg kg | 1125 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 1125 kgRetrieved 2026-10-01 |
| 2475 Lbs. Lbs. | 1122.64 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 2475 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1700 x 700 x 1000 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1700 x 700 x 1000 mmRetrieved 2026-10-01 |
| 1700 x 700 x 1000 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1700 x 700 x 1000 mmRetrieved 2026-10-01 |
| 66.9 x 27.6 x 39.4 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 66.9 x 27.6 x 39.4 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 100 ISORetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 100 ISORetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |