Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch COBRA DX 0650 A PLUS: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → COBRA DX 0650/0950 A PLUS → COBRA DX 0650 A PLUS

Manufacturer model: COBRA DX 0650 A PLUS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
max. 650 m³/h m³/h650 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: max. 650 m³/h
Retrieved 2026-10-01
max. 650 m³/h m³/h650 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: max. 650 m³/h
Retrieved 2026-10-01
382.5 ACFM ACFM649.8713 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 382.5 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 0.1 hPa (mbar) hPa (mbar)0.1 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: ≤ 0.1 hPa (mbar)
Retrieved 2026-10-01
≤ 0.1 hPa (mbar) hPa (mbar)0.1 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: ≤ 0.1 hPa (mbar)
Retrieved 2026-10-01
0.075 Torr Torr0.1 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: 0.075 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15 kW kW15 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 15 kW
Retrieved 2026-10-01
15 kW kW15 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 15 kW
Retrieved 2026-10-01
20 hp hp14.914 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 20 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3000 min⁻¹ min⁻¹3000 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3000 rpm rpm3000 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3000 rpm
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 67 dB(A) dB(A)67 dB(A)50 Hz · model
ISO 50 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
different frequency
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)
Retrieved 2026-10-01
≤ 67 dB(A) dB(A)67 dB(A)60 Hz · model
ISO 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)
Retrieved 2026-10-01
≤ 67 dB(A) dB(A)67 dB(A)60 Hz · model
US 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 67 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1125 kg kg1125 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 1125 kg
Retrieved 2026-10-01
1125 kg kg1125 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 1125 kg
Retrieved 2026-10-01
2475 Lbs. Lbs.1122.64 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 2475 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1700 x 700 x 1000 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1700 x 700 x 1000 mm
Retrieved 2026-10-01
1700 x 700 x 1000 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1700 x 700 x 1000 mm
Retrieved 2026-10-01
66.9 x 27.6 x 39.4 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 66.9 x 27.6 x 39.4 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 100 ISO
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected