Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch COBRA NC 1000 B: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → COBRA NC 0400–1000 B/C → COBRA NC 1000 B

Manufacturer model: COBRA NC 1000 B · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
840 m³/h m³/h840 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 840 m³/h
Retrieved 2026-10-01
1000 m³/h m³/h1000 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 1000 m³/h
Retrieved 2026-10-01
590 ACFM ACFM1002.416 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Pumping speed: 590 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 0.05 hPa (mbar) hPa (mbar)0.05 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Ultimate pressure: ≤ 0.05 hPa (mbar)
Retrieved 2026-10-01
≤ 0.01 hPa (mbar) hPa (mbar)0.01 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: ≤ 0.01 hPa (mbar)
Retrieved 2026-10-01
≤ 0.0075 Torr Torr0.01 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: ≤ 0.0075 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
22 kW kW22 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 22 kW
Retrieved 2026-10-01
25 kW kW25 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 25 kW
Retrieved 2026-10-01
40 hp hp29.828 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 40 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 rpm rpm3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 rpm
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 75 dB(A) dB(A)75 dB(A)50 Hz · model
ISO 50 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 75 dB(A)
Retrieved 2026-10-01
≤ 81 dB(A) dB(A)81 dB(A)60 Hz · model
ISO 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 81 dB(A)
Retrieved 2026-10-01
81 dB(A) dB(A)81 dB(A)60 Hz · model
US 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 2151), KpA = 3 dB: 81 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500 kg kg1500 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 1500 kg
Retrieved 2026-10-01
1500 kg kg1500 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 1500 kg
Retrieved 2026-10-01
3306 Lbs. Lbs.1499.575 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 3306 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1928 x 620 x 974 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1928 x 620 x 974 mm
Retrieved 2026-10-01
1928 x 620 x 974 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1928 x 620 x 974 mm
Retrieved 2026-10-01
75.9 x 24.4 x 38.3 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 75.9 x 24.4 x 38.3 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 125 PN 16 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 125 PN 16
Retrieved 2026-10-01
DN 125 PN 16 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 125 PN 16
Retrieved 2026-10-01
ANSI 150 (5 in) — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: ANSI 150 (5 in)
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 125 PN 16 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 125 PN 16
Retrieved 2026-10-01
DN 125 PN 16 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 125 PN 16
Retrieved 2026-10-01
NPT 5 in — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: NPT 5 in
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals70
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected