Data coverage & sources
The stored record for Busch COBRA NC 2500 C: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → COBRA NC 2500 C → COBRA NC 2500 C
Manufacturer model: COBRA NC 2500 C · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2000 m³/h m³/h | 2000 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 2000 m³/hRetrieved 2026-10-01 |
| 2500 m³/h m³/h | 2500 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 2500 m³/hRetrieved 2026-10-01 |
| 1471 ACFM ACFM | 2499.244 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_SOURCEPumping speed: 1471 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 1.0 hPa (mbar) hPa (mbar) | 1 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: ≤ 1.0 hPa (mbar)Retrieved 2026-10-01 |
| ≤ 1.0 hPa (mbar) hPa (mbar) | 1 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 1.0 hPa (mbar)Retrieved 2026-10-01 |
| ≤ 0.75 Torr Torr | 0.9999 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: ≤ 0.75 TorrRetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 55.0 kW kW | 55 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 55.0 kWRetrieved 2026-10-01 |
| 63.0 kW kW | 63 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 63.0 kWRetrieved 2026-10-01 |
| 84.5 hp hp | 63.0117 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 84.5 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 rpm rpm | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: 3600 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 79 dB(A) dB(A) | 79 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIED different frequency Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 79 dB(A)Retrieved 2026-10-01 |
| ≤ 79 dB(A) dB(A) | 79 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: ≤ 79 dB(A)Retrieved 2026-10-01 |
| 84 dB(A) dB(A) | 84 dB(A) | 60 Hz · model US 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_SOURCESound pressure level (ISO 2151), KpA = 3 dB: 84 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2500 kg kg | 2500 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 2500 kgRetrieved 2026-10-01 |
| 2500 kg kg | 2500 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 2500 kgRetrieved 2026-10-01 |
| 5511 Lbs. Lbs. | 2499.745 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: 5511 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2243 x 1053 x 1437 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 2243 x 1053 x 1437 mmRetrieved 2026-10-01 |
| 2243 x 1053 x 1437 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 2243 x 1053 x 1437 mmRetrieved 2026-10-01 |
| 88.3 x 41.5 x 56.6 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 88.3 x 41.5 x 56.6 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 150 PN 16 | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 150 PN 16Retrieved 2026-10-01 |
| DN 150 PN 16 | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 150 PN 16Retrieved 2026-10-01 |
| ANSI 150 (6 in) | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: ANSI 150 (6 in)Retrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 PN 16 | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 100 PN 16Retrieved 2026-10-01 |
| DN 100 PN 16 | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 100 PN 16Retrieved 2026-10-01 |
| NPT 4 in | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: NPT 4 inRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |