Data coverage & sources
The stored record for Busch COMBI BNV 2400 A 0950 AA: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → COMBI BN → COMBI BNV 2400 A 0950 AA
Manufacturer model: COMBI BNV 2400 A 0950 AA · OEM article / order number: Not collected · Equipment type: system
Technology: Central Vacuum Systems
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging
Related industries: Medical, Packaging
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
18 stored observations · 8 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Cobra Dry Screw Vacuum Pump · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| NX 0950 A | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency COBRA dry screw vacuum pump: NX 0950 ARetrieved 2026-10-01 |
| NX 0950 A | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCECOBRA dry screw vacuum pump: NX 0950 ARetrieved 2026-10-01 |
| NX 0950 A | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCECOBRA dry screw vacuum pump: NX 0950 ARetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 24.5 kW kW | 24.5 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 24.5 kWRetrieved 2026-10-01 |
| 26.1 kW kW | 26.1 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 26.1 kWRetrieved 2026-10-01 |
| 35.0 hp hp | 26.0995 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 35.0 hpRetrieved 2026-10-01 |
Panda Vacuum Booster · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| WV 2400 A | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency PANDA vacuum booster: WV 2400 ARetrieved 2026-10-01 |
| WV 2400 A | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEPANDA vacuum booster: WV 2400 ARetrieved 2026-10-01 |
| WV 2400 A | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEPANDA vacuum booster: WV 2400 ARetrieved 2026-10-01 |
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1930 m³/h m³/h | 1930 m3/h | 50 Hz · model ISO 50 Hz; at 1 mbar unspecified | Source · OEM_SOURCE different frequency Pumping speed at 1 mbar: 1930 m³/hRetrieved 2026-10-01 |
| 2300 m³/h m³/h | 2300 m3/h | 60 Hz · model ISO 60 Hz; at 1 mbar unspecified | Source · OEM_SOURCEPumping speed at 1 mbar: 2300 m³/hRetrieved 2026-10-01 |
| 1353.6 ACFM ACFM | 2299.78 m3/h | 60 Hz · model US 60 Hz; at 1 mbar actual inlet | Source · OEM_SOURCEPumping speed at 1 mbar: 1353.6 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 1 · 10⁻³ hPa(mbar) · 10⁻³ hPa(mbar) | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: ≤ 1 · 10⁻³ hPa(mbar)Retrieved 2026-10-01 |
| ≤ 1 · 10⁻³ hPa(mbar) · 10⁻³ hPa(mbar) | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 1 · 10⁻³ hPa(mbar)Retrieved 2026-10-01 |
| ≤ 0.75 · 10⁻³ TORR · 10⁻³ TORR | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 0.75 · 10⁻³ TORRRetrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1400 kg kg | 1400 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_SOURCE different frequency Weight approx.: 1400 kgRetrieved 2026-10-01 |
| 1400 kg kg | 1400 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: 1400 kgRetrieved 2026-10-01 |
| 3080 Lbs. Lbs. | 1397.063 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: 3080 Lbs.Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |