Data coverage & sources
The stored record for Busch COMBI BRV 0500 C A200 AA: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → COMBI BR → COMBI BRV 0500 C A200 AA
Manufacturer model: COMBI BRV 0500 C A200 AA · OEM article / order number: Not collected · Equipment type: system
Technology: Central Vacuum Systems
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging
Related industries: Medical, Packaging
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
18 stored observations · 8 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6.2 kW kW | 6.2 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 6.2 kWRetrieved 2026-10-01 |
| 7.8 kW kW | 7.8 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 7.8 kWRetrieved 2026-10-01 |
| 10.5 hp hp | 7.8299 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 10.5 hpRetrieved 2026-10-01 |
Panda Vacuum Booster · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| WV 0500 C | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency PANDA vacuum booster: WV 0500 CRetrieved 2026-10-01 |
| WV 0500 C | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEPANDA vacuum booster: WV 0500 CRetrieved 2026-10-01 |
| WV 0500 C | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEPANDA vacuum booster: WV 0500 CRetrieved 2026-10-01 |
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 465 m³/h m³/h | 465 m3/h | 50 Hz · model ISO 50 Hz; at 1 mbar unspecified | Source · OEM_SOURCE different frequency Pumping speed at 1 mbar: 465 m³/hRetrieved 2026-10-01 |
| 555 m³/h m³/h | 555 m3/h | 60 Hz · model ISO 60 Hz; at 1 mbar unspecified | Source · OEM_VERIFIEDPumping speed at 1 mbar: 555 m³/hRetrieved 2026-10-01 |
| 327 ACFM ACFM | 555.5763 m3/h | 60 Hz · model US 60 Hz; at 1 mbar actual inlet | Source · OEM_SOURCEPumping speed at 1 mbar: 327 ACFMRetrieved 2026-10-01 |
R5 Rotary Vane Vacuum Pump · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| RA 0200 A | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency R5 rotary vane vacuum pump: RA 0200 ARetrieved 2026-10-01 |
| RA 0200 A | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCER5 rotary vane vacuum pump: RA 0200 ARetrieved 2026-10-01 |
| RA 0200 A | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCER5 rotary vane vacuum pump: RA 0200 ARetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 1 · 10⁻² hPa(mbar) · 10⁻² hPa(mbar) | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: ≤ 1 · 10⁻² hPa(mbar)Retrieved 2026-10-01 |
| ≤ 1 · 10⁻² hPa(mbar) · 10⁻² hPa(mbar) | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 1 · 10⁻² hPa(mbar)Retrieved 2026-10-01 |
| ≤ 0.75 · 10⁻² TORR · 10⁻² TORR | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: ≤ 0.75 · 10⁻² TORRRetrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 390 kg kg | 390 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 390 kgRetrieved 2026-10-01 |
| 390 kg kg | 390 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 390 kgRetrieved 2026-10-01 |
| 860 Lbs. Lbs. | 390.0891 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: 860 Lbs.Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |