Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch DOLPHIN LG 0890 A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → DOLPHIN LG 0890/1200 A → DOLPHIN LG 0890 A

Manufacturer model: DOLPHIN LG 0890 A · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Liquid Ring

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Food + Beverage, Mining, Oil + Gas, Pharmaceutical, Plastics, Power Generation, Pulp + Paper, Water + Wastewater

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

29 stored observations · 17 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
6000 m³/h m³/h6000 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 6000 m³/h
Retrieved 2026-10-01
8900 m³/h m³/h8900 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 8900 m³/h
Retrieved 2026-10-01
5238.3 ACFM ACFM8899.924 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 5238.3 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
160 hPa (mbar) hPa (mbar)160 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: 160 hPa (mbar)
Retrieved 2026-10-01
160 hPa (mbar) hPa (mbar)160 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: 160 hPa (mbar)
Retrieved 2026-10-01
120 Torr Torr159.9864 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Ultimate pressure: 120 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
132 / 160 / 185 / 200 / 220 kW / 160 / 185 / 200 / 220 kW— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 132 / 160 / 185 / 200 / 220 kW
Retrieved 2026-10-01
132 / 160 / 185 / 200 / 220 kW / 160 / 185 / 200 / 220 kW— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 132 / 160 / 185 / 200 / 220 kW
Retrieved 2026-10-01
300.0 hp hp223.71 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 300.0 hp
Retrieved 2026-10-01
Speed · Needs review · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
330 – 490 min⁻¹ min⁻¹330 rpm50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Nominal motor speed: 330 – 490 min⁻¹
Retrieved 2026-10-01
330 – 490 min⁻¹ min⁻¹330 rpm60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Nominal motor speed: 330 – 490 min⁻¹
Retrieved 2026-10-01
330 – 490 rpm rpm330 rpm60 Hz · range
US 60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Nominal motor speed: 330 – 490 rpm
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
< 85 dB(A) dB(A)85 dB(A)50 Hz · model
ISO 50 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (ISO 3744), 1 m distance, at medium load: < 85 dB(A)
Retrieved 2026-10-01
< 85 dB(A) dB(A)85 dB(A)60 Hz · model
ISO 60 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 3744), 1 m distance, at medium load: < 85 dB(A)
Retrieved 2026-10-01
< 85 dB(A) dB(A)85 dB(A)60 Hz · model
US 60 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 3744), 1 m distance, at medium load: < 85 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3880 kg kg3880 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 3880 kg
Retrieved 2026-10-01
3880 kg kg3880 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 3880 kg
Retrieved 2026-10-01
8554 Lbs. Lbs.3880.026 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 8554 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2370 x 1330 x 1865 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 2370 x 1330 x 1865 mm
Retrieved 2026-10-01
2370 x 1330 x 1865 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 2370 x 1330 x 1865 mm
Retrieved 2026-10-01
93.3 x 52.4 x 73.4 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 93.3 x 52.4 x 73.4 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 300 PN 10 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 300 PN 10
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 300 PN 10 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 300 PN 10
Retrieved 2026-10-01
Max. overpressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.2 bar(g) bar(g)— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Max. overpressure: 0.2 bar(g)
Retrieved 2026-10-01
0.2 bar(g) bar(g)— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Max. overpressure: 0.2 bar(g)
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected