Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch DOLPHIN VX 0180 A Total Recirculation: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → DOLPHIN VX 0110-0180 A Total Recirculation → DOLPHIN VX 0180 A Total Recirculation

Manufacturer model: DOLPHIN VX 0180 A Total Recirculation · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Liquid Ring

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Food + Beverage, Mining, Oil + Gas, Pharmaceutical, Plastics, Power Generation, Pulp + Paper, Water + Wastewater

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 17 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
122 m³/h m³/h122 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 122 m³/h
Retrieved 2026-10-01
144 m³/h m³/h144 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 144 m³/h
Retrieved 2026-10-01
84.8 ACFM ACFM144.076 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 84.8 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
33 hPa (mbar) hPa (mbar)33 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: 33 hPa (mbar)
Retrieved 2026-10-01
33 hPa (mbar) hPa (mbar)33 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: 33 hPa (mbar)
Retrieved 2026-10-01
25 Torr Torr33.3305 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Ultimate pressure: 25 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4.0 kW kW4 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 4.0 kW
Retrieved 2026-10-01
5.5 kW kW5.5 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 5.5 kW
Retrieved 2026-10-01
7.5 hp hp5.5928 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 7.5 hp
Retrieved 2026-10-01
Speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1450 min⁻¹ min⁻¹1450 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 1450 min⁻¹
Retrieved 2026-10-01
1750 min⁻¹ min⁻¹1750 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Nominal motor speed: 1750 min⁻¹
Retrieved 2026-10-01
Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 70 dB(A) dB(A)70 dB(A)50 Hz · model
ISO 50 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (ISO 3744), 1 m distance, at medium load: ≤ 70 dB(A)
Retrieved 2026-10-01
≤ 70 dB(A) dB(A)70 dB(A)60 Hz · model
ISO 60 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 3744), 1 m distance, at medium load: ≤ 70 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
178 kg kg178 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_SOURCE
different frequency
Weight approx.: 178 kg
Retrieved 2026-10-01
195 kg kg195 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 195 kg
Retrieved 2026-10-01
430 Lbs. Lbs.195.0446 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 430 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
700 x 770 x 825 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 700 x 770 x 825 mm
Retrieved 2026-10-01
700 x 770 x 825 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 700 x 770 x 825 mm
Retrieved 2026-10-01
27.6 x 30.3 x 32.5 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 27.6 x 30.3 x 32.5 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
G 1½" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: G 1½"
Retrieved 2026-10-01
G 1½" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: G 1½"
Retrieved 2026-10-01
G1½" — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: G1½"
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
R 2" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: R 2"
Retrieved 2026-10-01
R 2" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: R 2"
Retrieved 2026-10-01
R2" — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: R2"
Retrieved 2026-10-01
Max. overpressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.5 bar(g) bar(g)— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Max. overpressure: 0.5 bar(g)
Retrieved 2026-10-01
0.5 bar(g) bar(g)— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Max. overpressure: 0.5 bar(g)
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications30
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected