Data coverage & sources
The stored record for Busch KD 0025 A long separator: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → R5 KD 0025 A → KD 0025 A long separator
Manufacturer model: KD 0025 A long separator · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Oil-Lubricated Rotary Vane
Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
30 stored observations · 20 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 22 m³/h m³/h | 22 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 22 m³/hRetrieved 2026-10-01 |
| 25 m³/h m³/h | 25 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal pumping speed: 25 m³/hRetrieved 2026-10-01 |
| 14.7 ACFM ACFM | 24.9754 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 14.7 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2.0 hPa (mbar) hPa (mbar) | 2 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Ultimate pressure: 2.0 hPa (mbar)Retrieved 2026-10-01 |
| 2.0 hPa (mbar) hPa (mbar) | 2 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: 2.0 hPa (mbar)Retrieved 2026-10-01 |
| 1.5 Torr Torr | 1.9998 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: 1.5 TorrRetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.75 kW kW | 0.75 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 0.75 kWRetrieved 2026-10-01 |
| 0.9 kW kW | 0.9 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 0.9 kWRetrieved 2026-10-01 |
| 1.2 hp hp | 0.8948 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor rating: 1.2 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 rpm rpm | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: 3600 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 64 dB(A) dB(A) | 64 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_SOURCE different frequency Sound pressure level (ISO 2151), KpA = 3 dB: 64 dB(A)Retrieved 2026-10-01 |
| 68 dB(A) dB(A) | 68 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_SOURCESound pressure level (ISO 2151), KpA = 3 dB: 68 dB(A)Retrieved 2026-10-01 |
| 68 dB(A) dB(A) | 68 dB(A) | 60 Hz · model US 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_SOURCESound pressure level (ISO 2151), KpA = 3 dB: 68 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 21 kg kg | 21 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_SOURCE different frequency Weight approx.: 21 kgRetrieved 2026-10-01 |
| 21 kg kg | 21 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: 21 kgRetrieved 2026-10-01 |
| 46.2 Lbs. Lbs. | 20.956 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 46.2 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 338 x 232 x 172 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 338 x 232 x 172 mmRetrieved 2026-10-01 |
| 338 x 232 x 172 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 338 x 232 x 172 mmRetrieved 2026-10-01 |
| 13.3 x 9.1 x 7.4 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 13.3 x 9.1 x 7.4 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G ½" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G ½"Retrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G ½" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: G ½"Retrieved 2026-10-01 |
Oil capacity · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.45 l l | 0.45 l | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Oil capacity: 0.45 lRetrieved 2026-10-01 |
| 0.45 l l | 0.45 l | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEOil capacity: 0.45 lRetrieved 2026-10-01 |
| 0.45 l l | 0.45 l | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEOil capacity: 0.45 lRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |