Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch MEDIVAC GMV3006305: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → MEDIVAC GMV3002105-GMH3132220 → MEDIVAC GMV3006305

Manufacturer model: MEDIVAC GMV3006305 · OEM article / order number: Not collected · Equipment type: system

Technology: Central Vacuum Systems

Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging
Related industries: Medical, Packaging

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

18 stored observations · 7 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2000 x 1210 x 2200 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 2000 x 1210 x 2200 mm
Retrieved 2026-10-01
2000 x 1210 x 2200 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 2000 x 1210 x 2200 mm
Retrieved 2026-10-01
Inlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
G 1½" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: G 1½"
Retrieved 2026-10-01
G 1½" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: G 1½"
Retrieved 2026-10-01
Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3 x 2.0 kW — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 3 x 2.0 kW
Retrieved 2026-10-01
3 x 2.0 kW — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 3 x 2.0 kW
Retrieved 2026-10-01
Outlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
G 1¼" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: G 1¼"
Retrieved 2026-10-01
G 1¼" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: G 1¼"
Retrieved 2026-10-01
Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
63 m³/h m³/h63 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 63 m³/h
Retrieved 2026-10-01
63 m³/h m³/h63 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 63 m³/h
Retrieved 2026-10-01
Vessel Position · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
vertical — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Vessel position: vertical
Retrieved 2026-10-01
vertical — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Vessel position: vertical
Retrieved 2026-10-01
Vessel Volume · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
500 l l500 l50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Vessel volume: 500 l
Retrieved 2026-10-01
500 l l500 l60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Vessel volume: 500 l
Retrieved 2026-10-01
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
650 kg kg650 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 650 kg
Retrieved 2026-10-01
650 kg kg650 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 650 kg
Retrieved 2026-10-01
Working pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
300 mbar(a) mbar(a)— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Working pressure: 300 mbar(a)
Retrieved 2026-10-01
300 mbar(a) mbar(a)— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Working pressure: 300 mbar(a)
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected