Data coverage & sources
The stored record for Busch MINK MB 0018 A: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → MINK MB 0018 A → MINK MB 0018 A
Manufacturer model: MINK MB 0018 A · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Claw
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging, Pick + Place, Pneumatic Conveying, Vacuum Forming, Vacuum Hold-Down
Related industries: Electronics, Food + Beverage, General Manufacturing, Medical, Packaging, Plastics, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
30 stored observations · 20 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 18 m³/h m³/h | 18 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 18 m³/hRetrieved 2026-10-01 |
| 18 m³/h m³/h | 18 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 18 m³/hRetrieved 2026-10-01 |
| 10.6 ACFM ACFM | 18.0095 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 10.6 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 600 hPa (mbar) hPa (mbar) | 600 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Ultimate pressure: 600 hPa (mbar)Retrieved 2026-10-01 |
| 450 hPa (mbar) hPa (mbar) | 450 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 450 hPa (mbar)Retrieved 2026-10-01 |
| 450 TORR TORR | 599.949 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 450 TORRRetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.5 kW kW | 0.5 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 0.5 kWRetrieved 2026-10-01 |
| 0.5 kW kW | 0.5 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 0.5 kWRetrieved 2026-10-01 |
| 0.7 hp hp | 0.522 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 0.7 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6000 min⁻¹ min⁻¹ | 6000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 6000 min⁻¹Retrieved 2026-10-01 |
| 6000 min⁻¹ min⁻¹ | 6000 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 6000 min⁻¹Retrieved 2026-10-01 |
| 6000 rpm rpm | 6000 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: 6000 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 73 dB(A) dB(A) | 73 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIED different frequency Sound pressure level (ISO 2151), KpA = 3 dB: 73 dB(A)Retrieved 2026-10-01 |
| 73 dB(A) dB(A) | 73 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: 73 dB(A)Retrieved 2026-10-01 |
| 73 dB(A) dB(A) | 73 dB(A) | 60 Hz · model US 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: 73 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6.5 kg kg | 6.5 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 6.5 kgRetrieved 2026-10-01 |
| 6.5 kg kg | 6.5 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 6.5 kgRetrieved 2026-10-01 |
| 14.3 Lbs. Lbs. | 6.4864 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 14.3 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 329.5 x 120 x 199 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 329.5 x 120 x 199 mmRetrieved 2026-10-01 |
| 329.5 x 120 x 199 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 329.5 x 120 x 199 mmRetrieved 2026-10-01 |
| 13 x 4.7 x 7.8 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 13 x 4.7 x 7.8 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G ¾" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: G ¾"Retrieved 2026-10-01 |
| G ¾" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G ¾"Retrieved 2026-10-01 |
| G ¾" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G ¾"Retrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G ½" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: G ½"Retrieved 2026-10-01 |
| G ½" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: G ½"Retrieved 2026-10-01 |
Ambient temperature · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| -40 … +40 °C … +40 °C | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ambient temperature: -40 … +40 °CRetrieved 2026-10-01 |
| -40 … +40 °C … +40 °C | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDAmbient temperature: -40 … +40 °CRetrieved 2026-10-01 |
| -104 … +104 °F … +104 °F | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDAmbient temperature: -104 … +104 °FRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |