Compare coverage across this familySpecifications and evidence
16 stored observations · 8 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 110 m³/h m³/h | 110 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 110 m³/hRetrieved 2026-10-01 |
| - m³/h | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal pumping speed: - m³/hRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 hPa (mbar) hPa (mbar) | 400 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: 400 hPa (mbar)Retrieved 2026-10-01 |
| - hPa (mbar) | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: - hPa (mbar)Retrieved 2026-10-01 |
Motor power · Sourced · 2 observations / 1 sources
Speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| - min⁻¹ | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: - min⁻¹Retrieved 2026-10-01 |
Noise level · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 70 dB(A) dB(A) | 70 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 3744), 1 m distance, at medium load unspecified | Source · OEM_SOURCE different frequency Sound pressure level (ISO 3744), 1 m distance, at medium load: 70 dB(A)Retrieved 2026-10-01 |
| - dB(A) | — | 60 Hz · model ISO 60 Hz; (ISO 3744), 1 m distance, at medium load unspecified | Source · OEM_SOURCESound pressure level (ISO 3744), 1 m distance, at medium load: - dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 140 kg kg | 140 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 140 kgRetrieved 2026-10-01 |
| - kg | — | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_SOURCEWeight approx.: - kgRetrieved 2026-10-01 |
Dimensions · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 898 x 339 x 301 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 898 x 339 x 301 mmRetrieved 2026-10-01 |
| - x - x - mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): - x - x - mmRetrieved 2026-10-01 |
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Oil capacity · Sourced · 2 observations / 1 sources
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |