Data coverage & sources
The stored record for Busch MINK MV 0500 B: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → MINK MV 0500/0600 B → MINK MV 0500 B
Manufacturer model: MINK MV 0500 B · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Claw
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging, Pick + Place, Pneumatic Conveying, Vacuum Forming, Vacuum Hold-Down
Related industries: Electronics, Food + Beverage, General Manufacturing, Medical, Packaging, Plastics, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
30 stored observations · 17 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 470 m³/h m³/h | 470 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 470 m³/hRetrieved 2026-10-01 |
| 470 m³/h m³/h | 470 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 470 m³/hRetrieved 2026-10-01 |
| 276.6 ACFM ACFM | 469.9462 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 276.6 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 hPa (mbar) hPa (mbar) | 200 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: 200 hPa (mbar)Retrieved 2026-10-01 |
| 200 hPa (mbar) hPa (mbar) | 200 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 200 hPa (mbar)Retrieved 2026-10-01 |
| 150 TORR TORR | 199.983 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 150 TORRRetrieved 2026-10-01 |
Motor power · Needs review · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 11.0 – 12.6 kW kW | 11 kW | 50 Hz · range ISO 50 Hz unspecified | Source · OEM_VERIFIED not a model rating, different frequency Nominal motor rating: 11.0 – 12.6 kWRetrieved 2026-10-01 |
| 11.0 – 12.6 kW kW | 11 kW | 60 Hz · range ISO 60 Hz unspecified | Source · OEM_VERIFIED not a model rating Nominal motor rating: 11.0 – 12.6 kWRetrieved 2026-10-01 |
| 14.8 – 16.9 hp hp | 11.0364 kW | 60 Hz · range US 60 Hz unspecified | Source · OEM_VERIFIED not a model rating Nominal motor rating: 14.8 – 16.9 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1200 – 3600 min⁻¹ min⁻¹ | 1200 rpm | 50 Hz · range ISO 50 Hz unspecified | Source · OEM_VERIFIED not a model rating, different frequency Nominal motor speed: 1200 – 3600 min⁻¹Retrieved 2026-10-01 |
| 1200 – 3600 min⁻¹ min⁻¹ | 1200 rpm | 60 Hz · range ISO 60 Hz unspecified | Source · OEM_VERIFIED not a model rating Nominal motor speed: 1200 – 3600 min⁻¹Retrieved 2026-10-01 |
| 1200 ... 3600 rpm rpm | 1200 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCENominal motor speed: 1200 ... 3600 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 76 dB(A) dB(A) | 76 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 3744), 1 m distance, at medium load unspecified | Source · OEM_SOURCE different frequency Sound pressure level (ISO 3744), 1 m distance, at medium load: 76 dB(A)Retrieved 2026-10-01 |
| 76 dB(A) dB(A) | 76 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 3744), 1 m distance, at medium load unspecified | Source · OEM_SOURCESound pressure level (ISO 3744), 1 m distance, at medium load: 76 dB(A)Retrieved 2026-10-01 |
| 75 dB(A) dB(A) | 75 dB(A) | 60 Hz · model US 60 Hz; (ISO 3744), 1 m distance, at medium load unspecified | Source · OEM_SOURCESound pressure level (ISO 3744), 1 m distance, at medium load: 75 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 495 kg kg | 495 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 495 kgRetrieved 2026-10-01 |
| 495 kg kg | 495 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 495 kgRetrieved 2026-10-01 |
| 1089 Lbs. Lbs. | 493.9617 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 1089 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1195 x 580 x 795 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1195 x 580 x 795 mmRetrieved 2026-10-01 |
| 1195 x 580 x 795 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1195 x 580 x 795 mmRetrieved 2026-10-01 |
| 47 x 22.8 x 31.3 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 47 x 22.8 x 31.3 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| G 3" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: G 3"Retrieved 2026-10-01 |
| G 3" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G 3"Retrieved 2026-10-01 |
| G 3" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: G 3"Retrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| R 2" | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: R 2"Retrieved 2026-10-01 |
| R 2" | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: R 2"Retrieved 2026-10-01 |
| R 2" | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: R 2"Retrieved 2026-10-01 |
Oil capacity · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.2 l l | 1.2 l | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Oil capacity: 1.2 lRetrieved 2026-10-01 |
| 1.2 l l | 1.2 l | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEOil capacity: 1.2 lRetrieved 2026-10-01 |
| 1.3 qts. qts. | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEOil capacity: 1.3 qts.Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |