Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PANDA WV 0250 C: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PANDA WV 0250/0500 C → PANDA WV 0250 C

Manufacturer model: PANDA WV 0250 C · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

33 stored observations · 22 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 m³/h m³/h250 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 250 m³/h
Retrieved 2026-10-01
235 m³/h m³/h235 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed: 235 m³/h
Retrieved 2026-10-01
300 m³/h m³/h300 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 300 m³/h
Retrieved 2026-10-01
285 m³/h m³/h285 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Pumping speed: 285 m³/h
Retrieved 2026-10-01
176.6 ACFM ACFM300.0452 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 176.6 ACFM
Retrieved 2026-10-01
167.7 ACFM ACFM284.924 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Pumping speed: 167.7 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1.0 kW kW1 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 1.0 kW
Retrieved 2026-10-01
1.2 kW kW1.2 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 1.2 kW
Retrieved 2026-10-01
2.0 hp hp1.4914 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 2.0 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500 min⁻¹ min⁻¹1500 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 1500 min⁻¹
Retrieved 2026-10-01
1800 min⁻¹ min⁻¹1800 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 1800 min⁻¹
Retrieved 2026-10-01
1800 RPM RPM1800 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 1800 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
146 kg kg146 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 146 kg
Retrieved 2026-10-01
146 kg kg146 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 146 kg
Retrieved 2026-10-01
322 Lbs. Lbs.146.0566 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 322 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
904 x 352 x 422 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 904 x 352 x 422 mm
Retrieved 2026-10-01
904 x 352 x 422 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 904 x 352 x 422 mm
Retrieved 2026-10-01
35.6 x 13.9 x 16.6 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 35.6 x 13.9 x 16.6 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
Outlet connection · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 063 ISO — 50 Hz · model
ISO 50 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (horizontal): DN 063 ISO
Retrieved 2026-10-01
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 063 ISO — 60 Hz · model
ISO 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas outlet (horizontal): DN 063 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 063 ISO — 60 Hz · model
US 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas outlet (horizontal): DN 063 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
85 hPa (mbar) hPa (mbar)85 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 85 hPa (mbar)
Retrieved 2026-10-01
85 hPa (mbar) hPa (mbar)85 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 85 hPa (mbar)
Retrieved 2026-10-01
75 TORR TORR99.9915 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 75 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications30
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected