Data coverage & sources
The stored record for Busch PANDA WV 1800 A: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PANDA WV 1200–2400 A → PANDA WV 1800 A
Manufacturer model: PANDA WV 1800 A · OEM article / order number: 1311205150 · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
33 stored observations · 22 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1600 m³/h m³/h | 1600 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 1600 m³/hRetrieved 2026-10-01 |
| 1443 m³/h m³/h | 1443 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Pumping speed: 1443 m³/hRetrieved 2026-10-01 |
| 1920 m³/h m³/h | 1920 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 1920 m³/hRetrieved 2026-10-01 |
| 1718 m³/h m³/h | 1718 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDPumping speed: 1718 m³/hRetrieved 2026-10-01 |
| 1130.0 ACFM ACFM | 1919.881 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 1130.0 ACFMRetrieved 2026-10-01 |
| 1011.0 ACFM ACFM | 1717.699 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDPumping speed: 1011.0 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.3 kW kW | 4.3 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 4.3 kWRetrieved 2026-10-01 |
| 5.2 kW kW | 5.2 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 5.2 kWRetrieved 2026-10-01 |
| 7.5 hp hp | 5.5928 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 7.5 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 300 kg kg | 300 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 300 kgRetrieved 2026-10-01 |
| 300 kg kg | 300 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 300 kgRetrieved 2026-10-01 |
| 661 Lbs. Lbs. | 299.8243 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 661 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1114 x 470 x 398 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1114 x 470 x 398 mmRetrieved 2026-10-01 |
| 1114 x 470 x 398 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1114 x 470 x 398 mmRetrieved 2026-10-01 |
| 46.7 x 18.5 x 21.4 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 46.7 x 18.5 x 21.4 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas inlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas inlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas inlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas inlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| ANSI 4" | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas inlet (horizontal): ANSI 4"Retrieved 2026-10-01 |
| ANSI 4" | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas inlet (vertical): ANSI 4"Retrieved 2026-10-01 |
Outlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas outlet (horizontal): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas outlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas outlet (horizontal): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas outlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| ANSI 4" | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas outlet (horizontal): ANSI 4"Retrieved 2026-10-01 |
| ANSI 4" | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas outlet (vertical): ANSI 4"Retrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 53 hPa (mbar) hPa (mbar) | 53 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 53 hPa (mbar)Retrieved 2026-10-01 |
| 53 hPa (mbar) hPa (mbar) | 53 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 53 hPa (mbar)Retrieved 2026-10-01 |
| 40 TORR TORR | 53.3288 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 40 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |