Manufacturer model: PANDA WV 2200 A · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
20 stored observations · 8 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2155 m³/h m³/h | 2155 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 2155 m³/hRetrieved 2026-10-01 |
| 1876 m³/h m³/h | 1876 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Pumping speed: 1876 m³/hRetrieved 2026-10-01 |
| 2585 m³/h m³/h | 2585 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 2585 m³/hRetrieved 2026-10-01 |
| 2234 m³/h m³/h | 2234 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDPumping speed: 2234 m³/hRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.5 kW kW | 5.5 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 5.5 kWRetrieved 2026-10-01 |
| 6.3 kW kW | 6.3 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 6.3 kWRetrieved 2026-10-01 |
Speed · Needs review · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1500-3600 min⁻¹ min⁻¹ | 1500 rpm | 50 Hz · range ISO 50 Hz unspecified | Source · OEM_VERIFIED not a model rating, different frequency Nominal motor speed: 1500-3600 min⁻¹Retrieved 2026-10-01 |
| 1500-3600 min⁻¹ min⁻¹ | 1500 rpm | 60 Hz · range ISO 60 Hz unspecified | Source · OEM_VERIFIED not a model rating Nominal motor speed: 1500-3600 min⁻¹Retrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 340 kg kg | 340 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 340 kgRetrieved 2026-10-01 |
| 340 kg kg | 340 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 340 kgRetrieved 2026-10-01 |
Dimensions · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1297 x 502 x 458 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1297 x 502 x 458 mmRetrieved 2026-10-01 |
| 1297 x 502 x 458 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1297 x 502 x 458 mmRetrieved 2026-10-01 |
Inlet connection · Sourced · 2 observations / 1 sources
Outlet connection · Sourced · 2 observations / 1 sources
Atex Classification · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Ex II 3/3G Ex h IIB T3 Gc X / Ex II 2/2G Ex h IIB T3 Gb X* | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency ATEX classification: Ex II 3/3G Ex h IIB T3 Gc X / Ex II 2/2G Ex h IIB T3 Gb X*Retrieved 2026-10-01 |
| Ex II 3/3G Ex h IIB T3 Gc X / Ex II 2/2G Ex h IIB T3 Gb X* | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEATEX classification: Ex II 3/3G Ex h IIB T3 Gc X / Ex II 2/2G Ex h IIB T3 Gb X*Retrieved 2026-10-01 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 35 hPa (mbar) hPa (mbar) | 35 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 35 hPa (mbar)Retrieved 2026-10-01 |
| 35 hPa (mbar) hPa (mbar) | 35 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 35 hPa (mbar)Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |