Data coverage & sources
The stored record for Busch PANDA WZ 2400 A: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PANDA WZ 0250–2400 A/B → PANDA WZ 2400 A
Manufacturer model: PANDA WZ 2400 A · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
36 stored observations · 22 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2120 m³/h m³/h | 2120 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 2120 m³/hRetrieved 2026-10-01 |
| 1830 m³/h m³/h | 1830 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Pumping speed: 1830 m³/hRetrieved 2026-10-01 |
| 2540 m³/h m³/h | 2540 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 2540 m³/hRetrieved 2026-10-01 |
| 2158 m³/h m³/h | 2158 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDPumping speed: 2158 m³/hRetrieved 2026-10-01 |
| 1494.8 ACFM ACFM | 2539.68 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 1494.8 ACFMRetrieved 2026-10-01 |
| 1270 ACFM ACFM | 2157.743 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDPumping speed: 1270 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.5 kW kW | 5.5 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 5.5 kWRetrieved 2026-10-01 |
| 6.6 kW kW | 6.6 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 6.6 kWRetrieved 2026-10-01 |
| 8.9 hp hp | 6.6367 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 8.9 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 515 kg kg | 515 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 515 kgRetrieved 2026-10-01 |
| 515 kg kg | 515 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 515 kgRetrieved 2026-10-01 |
| 1133 Lbs. Lbs. | 513.9197 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 1133 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1089 x 568 x 503 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1089 x 568 x 503 mmRetrieved 2026-10-01 |
| 1089 x 568 x 503 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1089 x 568 x 503 mmRetrieved 2026-10-01 |
| 42.9 x 22.4 x 19.8 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 42.9 x 22.4 x 19.8 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas inlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas inlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas inlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas inlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas inlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas inlet (vertical): DN 160 ISORetrieved 2026-10-01 |
Outlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas outlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas outlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas outlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas outlet (vertical): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas outlet (horizontal): DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCEGas outlet (vertical): DN 160 ISORetrieved 2026-10-01 |
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: ≤ 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| ≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: ≤ 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| ≤ 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: ≤ 0.75 · 10⁻⁷ mbar · l/sRetrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 53 hPa (mbar) hPa (mbar) | 53 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 53 hPa (mbar)Retrieved 2026-10-01 |
| 53 hPa (mbar) hPa (mbar) | 53 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 53 hPa (mbar)Retrieved 2026-10-01 |
| 39.75 TORR TORR | 52.9955 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 39.75 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |