Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WG 9600: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WG 9600 A → PUMA WG 9600

Manufacturer model: PUMA WG 9600 · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

22 stored observations · 7 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4000-12000 m³/h m³/h4000 m3/h50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Nominal pumping speed: 4000-12000 m³/h
Retrieved 2026-10-01
7410 m³/h m³/h7410 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed: 7410 m³/h
Retrieved 2026-10-01
8000 m³/h m³/h8000 m3/h50 Hz · model
ISO 50 Hz; category
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed category: 8000 m³/h
Retrieved 2026-10-01
4000-12000 m³/h m³/h4000 m3/h60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Nominal pumping speed: 4000-12000 m³/h
Retrieved 2026-10-01
8747 m³/h m³/h8747 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Pumping speed: 8747 m³/h
Retrieved 2026-10-01
8000 m³/h m³/h8000 m3/h60 Hz · model
ISO 60 Hz; category
unspecified
Source · OEM_SOURCE
Pumping speed category: 8000 m³/h
Retrieved 2026-10-01
Ultimate pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
130 hPa hPa130 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Ultimate pressure: 130 hPa
Retrieved 2026-10-01
130 hPa hPa130 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Ultimate pressure: 130 hPa
Retrieved 2026-10-01
Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Needs review · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
750-2250 min⁻¹ min⁻¹750 rpm50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Nominal motor speed: 750-2250 min⁻¹
Retrieved 2026-10-01
750-2250 min⁻¹ min⁻¹750 rpm60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Nominal motor speed: 750-2250 min⁻¹
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500 kg kg1500 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_SOURCE
different frequency
Weight approx.: 1500 kg
Retrieved 2026-10-01
1500 kg kg1500 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_SOURCE
Weight approx.: 1500 kg
Retrieved 2026-10-01
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1384 x 860 x 810 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1384 x 860 x 810
Retrieved 2026-10-01
1384 x 860 x 810 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1384 x 860 x 810
Retrieved 2026-10-01
Inlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 300 PN 10 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 300 PN 10
Retrieved 2026-10-01
Outlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 300 PN 10 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 300 PN 10
Retrieved 2026-10-01
DN 300 PN 10 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 300 PN 10
Retrieved 2026-10-01
Ambient temperature · Needs review · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5-40 °C °C5 °C50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Ambient temperature: 5-40 °C
Retrieved 2026-10-01
5-40 °C °C5 °C60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Ambient temperature: 5-40 °C
Retrieved 2026-10-01
Cooling Gas Connection · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
DN 150 PN 10 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Cooling gas connection: DN 150 PN 10
Retrieved 2026-10-01
DN 150 PN 10 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Cooling gas connection: DN 150 PN 10
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected