Data coverage & sources
The stored record for Busch PUMA WP 2000 D2: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PUMA WP 1250–4500 B2/D2 → PUMA WP 2000 D2
Manufacturer model: PUMA WP 2000 D2 · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2020 m³/h m³/h | 2020 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed: 2020 m³/hRetrieved 2026-10-01 |
| 1791 m³/h m³/h | 1791 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Pumping speed: 1791 m³/hRetrieved 2026-10-01 |
| 2435 m³/h m³/h | 2435 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 2435 m³/hRetrieved 2026-10-01 |
| 2136 m³/h m³/h | 2136 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDPumping speed: 2136 m³/hRetrieved 2026-10-01 |
| 1435 ACFM ACFM | 2438.079 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 1435 ACFMRetrieved 2026-10-01 |
| 1247 ACFM ACFM | 2118.666 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDPumping speed: 1247 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.5 kW kW | 5.5 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 5.5 kWRetrieved 2026-10-01 |
| 7.0 kW kW | 7 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 7.0 kWRetrieved 2026-10-01 |
| 10.2 hp hp | 7.6061 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 10.2 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 350 kg kg | 350 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 350 kgRetrieved 2026-10-01 |
| 350 kg kg | 350 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 350 kgRetrieved 2026-10-01 |
| 730 Lbs. Lbs. | 331.1222 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 730 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1156 x 420 x 600 | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1156 x 420 x 600Retrieved 2026-10-01 |
| 1156 x 420 x 600 | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1156 x 420 x 600Retrieved 2026-10-01 |
| 44.8 x 15.4 x 23.9 | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 44.8 x 15.4 x 23.9Retrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO-F | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISO-FRetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO-F | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 160 ISO-FRetrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 50 hPa (mbar) hPa (mbar) | 50 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 50 hPa (mbar)Retrieved 2026-10-01 |
| 50 hPa (mbar) hPa (mbar) | 50 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 50 hPa (mbar)Retrieved 2026-10-01 |
| 30 TORR TORR | 39.9966 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 30 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |