Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WP 2000 D2: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WP 1250–4500 B2/D2 → PUMA WP 2000 D2

Manufacturer model: PUMA WP 2000 D2 · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2020 m³/h m³/h2020 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 2020 m³/h
Retrieved 2026-10-01
1791 m³/h m³/h1791 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed: 1791 m³/h
Retrieved 2026-10-01
2435 m³/h m³/h2435 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 2435 m³/h
Retrieved 2026-10-01
2136 m³/h m³/h2136 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Pumping speed: 2136 m³/h
Retrieved 2026-10-01
1435 ACFM ACFM2438.079 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 1435 ACFM
Retrieved 2026-10-01
1247 ACFM ACFM2118.666 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Pumping speed: 1247 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.5 kW kW5.5 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 5.5 kW
Retrieved 2026-10-01
7.0 kW kW7 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 7.0 kW
Retrieved 2026-10-01
10.2 hp hp7.6061 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 10.2 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 RPM RPM3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
350 kg kg350 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 350 kg
Retrieved 2026-10-01
350 kg kg350 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 350 kg
Retrieved 2026-10-01
730 Lbs. Lbs.331.1222 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 730 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1156 x 420 x 600 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1156 x 420 x 600
Retrieved 2026-10-01
1156 x 420 x 600 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1156 x 420 x 600
Retrieved 2026-10-01
44.8 x 15.4 x 23.9 — 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 44.8 x 15.4 x 23.9
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO-F
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 160 ISO-F
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
50 hPa (mbar) hPa (mbar)50 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
50 hPa (mbar) hPa (mbar)50 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
30 TORR TORR39.9966 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 30 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected