Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WP 5400 A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WP 5400/8100 A → PUMA WP 5400 A

Manufacturer model: PUMA WP 5400 A · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

22 stored observations · 7 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2700-6480 m³/h m³/h2700 m3/h50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
not a model rating, different frequency
Nominal pumping speed: 2700-6480 m³/h
Retrieved 2026-10-01
4754* m³/h * m³/h— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Pumping speed: 4754* m³/h
Retrieved 2026-10-01
2700-6480 m³/h m³/h2700 m3/h60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
not a model rating
Nominal pumping speed: 2700-6480 m³/h
Retrieved 2026-10-01
4836 m³/h m³/h4836 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Pumping speed: 4836 m³/h
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11 kW kW11 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 11 kW
Retrieved 2026-10-01
11 kW kW11 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 11 kW
Retrieved 2026-10-01
Speed · Needs review · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500-3600 min⁻¹ min⁻¹1500 rpm50 Hz · range
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
not a model rating, different frequency
Nominal motor speed: 1500-3600 min⁻¹
Retrieved 2026-10-01
1500-3600 min⁻¹ min⁻¹1500 rpm60 Hz · range
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
not a model rating
Nominal motor speed: 1500-3600 min⁻¹
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
810 kg kg810 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 810 kg
Retrieved 2026-10-01
810 kg kg810 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 810 kg
Retrieved 2026-10-01
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1716 x 589 x 490 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1716 x 589 x 490
Retrieved 2026-10-01
1716 x 589 x 490 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1716 x 589 x 490
Retrieved 2026-10-01
Inlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 250 PN16 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 250 PN16
Retrieved 2026-10-01
DN 250 PN16 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 250 PN16
Retrieved 2026-10-01
Outlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 250 PN16 — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 250 PN16
Retrieved 2026-10-01
DN 250 PN16 — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 250 PN16
Retrieved 2026-10-01
Atex Classification · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Ex II 2/2G Ex h IIB T4…T2 Gb X / Ex II 2/2G Ex h IIC T4...T2 Gb X* — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
ATEX classification: Ex II 2/2G Ex h IIB T4…T2 Gb X / Ex II 2/2G Ex h IIC T4...T2 Gb X*
Retrieved 2026-10-01
Ex II 2/2G Ex h IIB T4…T2 Gb X / Ex II 2/2G Ex h IIC T4...T2 Gb X* — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
ATEX classification: Ex II 2/2G Ex h IIB T4…T2 Gb X / Ex II 2/2G Ex h IIC T4...T2 Gb X*
Retrieved 2026-10-01
Cooling Method · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Water cooling — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Cooling method: Water cooling
Retrieved 2026-10-01
Water cooling — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Cooling method: Water cooling
Retrieved 2026-10-01
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
30 hPa (mbar) hPa (mbar)30 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 30 hPa (mbar)
Retrieved 2026-10-01
30 hPa (mbar) hPa (mbar)30 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 30 hPa (mbar)
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected