Data coverage & sources
The stored record for Busch PUMA WY 3600 A <sup>(2)</sup>: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PUMA WY 3600 A → PUMA WY 3600 A <sup>(2)</sup>
Manufacturer model: PUMA WY 3600 A <sup>(2)</sup> · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
30 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3600 m³/h m³/h | 3600 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 3600 m³/hRetrieved 2026-10-01 |
| 2945 m³/h <sup>(1)</sup> m³/h <sup>(1)</sup> | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Pumping speed: 2945 m³/h <sup>(1)</sup>Retrieved 2026-10-01 |
| 3600 m³/h m³/h | 3600 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 3600 m³/hRetrieved 2026-10-01 |
| 3040 m³/h <sup>(1)</sup> m³/h <sup>(1)</sup> | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEPumping speed: 3040 m³/h <sup>(1)</sup>Retrieved 2026-10-01 |
| 2118 ACFM ACFM | 3598.503 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIEDNominal pumping speed: 2118 ACFMRetrieved 2026-10-01 |
| 1789 ACFM <sup>(1)</sup> ACFM <sup>(1)</sup> | — | 60 Hz · model US 60 Hz actual inlet | Source · OEM_SOURCEPumping speed: 1789 ACFM <sup>(1)</sup>Retrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15 kW kW | 15 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 15 kWRetrieved 2026-10-01 |
| 15 kW kW | 15 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 15 kWRetrieved 2026-10-01 |
| 20.1 hp hp | 14.9886 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor rating: 20.1 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5400 min⁻¹ min⁻¹ | 5400 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 5400 min⁻¹Retrieved 2026-10-01 |
| 5400 min⁻¹ min⁻¹ | 5400 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 5400 min⁻¹Retrieved 2026-10-01 |
| 5400 RPM RPM | 5400 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 5400 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 500 kg kg | 500 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 500 kgRetrieved 2026-10-01 |
| 500 kg kg | 500 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 500 kgRetrieved 2026-10-01 |
| 1100 Lbs. Lbs. | 498.9512 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 1100 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1139 x 524 x 480 | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 1139 x 524 x 480Retrieved 2026-10-01 |
| 1139 x 524 x 480 | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1139 x 524 x 480Retrieved 2026-10-01 |
| 44.8 x 21.4 x 18.9 | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 44.8 x 21.4 x 18.9Retrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISORetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 160 ISORetrieved 2026-10-01 |
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: < 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| < 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: < 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| < 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: < 0.75 · 10⁻⁷ mbar · l/sRetrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 30 hPa (mbar) hPa (mbar) | 30 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 30 hPa (mbar)Retrieved 2026-10-01 |
| 30 hPa (mbar) hPa (mbar) | 30 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 30 hPa (mbar)Retrieved 2026-10-01 |
| 22.5 TORR TORR | 29.9975 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 22.5 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |