Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WY 8000 A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WY 8000 A → PUMA WY 8000 A

Manufacturer model: PUMA WY 8000 A · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

30 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
8100 m³/h m³/h8100 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 8100 m³/h
Retrieved 2026-10-01
5920 m³/h m³/h5920 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Pumping speed: 5920 m³/h
Retrieved 2026-10-01
8100 m³/h m³/h8100 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 8100 m³/h
Retrieved 2026-10-01
5920 m³/h m³/h5920 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Pumping speed: 5920 m³/h
Retrieved 2026-10-01
4770 ACFM ACFM8104.278 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 4770 ACFM
Retrieved 2026-10-01
3485 ACFM ACFM5921.05 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Pumping speed: 3485 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11 kW kW11 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 11 kW
Retrieved 2026-10-01
11 kW kW11 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 11 kW
Retrieved 2026-10-01
15 hp hp11.1855 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 15 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5400 min⁻¹ min⁻¹5400 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 5400 min⁻¹
Retrieved 2026-10-01
5400 min⁻¹ min⁻¹5400 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 5400 min⁻¹
Retrieved 2026-10-01
5400 RPM RPM5400 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 5400 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
515 kg kg515 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 515 kg
Retrieved 2026-10-01
515 kg kg515 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 515 kg
Retrieved 2026-10-01
1140 Lbs. Lbs.517.0949 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 1140 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1283 x 543 x 475 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1283 x 543 x 475
Retrieved 2026-10-01
1283 x 543 x 475 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1283 x 543 x 475
Retrieved 2026-10-01
50.5 x 21.4 x 18.7 — 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 50.5 x 21.4 x 18.7
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 250 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 250 ISO
Retrieved 2026-10-01
DN 250 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 250 ISO
Retrieved 2026-10-01
DN 250 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 250 ISO-F
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO-F
Retrieved 2026-10-01
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
< 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Leakage rate: < 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
< 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: < 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
< 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s— 60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: < 0.75 · 10⁻⁷ mbar · l/s
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15 hPa (mbar) hPa (mbar)15 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 15 hPa (mbar)
Retrieved 2026-10-01
15 hPa (mbar) hPa (mbar)15 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 15 hPa (mbar)
Retrieved 2026-10-01
11.25 TORR TORR14.9987 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 11.25 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected