Data coverage & sources
The stored record for Busch SAMOS SI 2200 E1: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → SAMOS SI 1500/2200 E1 → SAMOS SI 2200 E1
Manufacturer model: SAMOS SI 2200 E1 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
32 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2200 m³/h m³/h | 2200 m3/h | 50 Hz · model ISO 50 Hz; /volume flow unspecified | Source · OEM_SOURCE different frequency Nominal pumping speed/volume flow: 2200 m³/hRetrieved 2026-10-01 |
| 2640 m³/h m³/h | 2640 m3/h | 60 Hz · model ISO 60 Hz; /volume flow unspecified | Source · OEM_VERIFIEDNominal pumping speed/volume flow: 2640 m³/hRetrieved 2026-10-01 |
| 1553.6 ACFM ACFM | 2639.582 m3/h | 60 Hz · model US 60 Hz; /volume flow actual inlet | Source · OEM_VERIFIEDNominal pumping speed/volume flow: 1553.6 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 82 dB(A) dB(A) | 82 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 3744) unspecified | Source · OEM_SOURCE different frequency Noise level (ISO 3744): 82 dB(A)Retrieved 2026-10-01 |
| 84 dB(A) dB(A) | 84 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 3744) unspecified | Source · OEM_VERIFIEDNoise level (ISO 3744): 84 dB(A)Retrieved 2026-10-01 |
| 84 dB(A) dB(A) | 84 dB(A) | 60 Hz · model US 60 Hz; (ISO 3744) unspecified | Source · OEM_VERIFIEDNoise level (ISO 3744): 84 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 166 kg kg | 166 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 166 kgRetrieved 2026-10-01 |
| 166 kg kg | 166 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 166 kgRetrieved 2026-10-01 |
| 365.2 Lbs. Lbs. | 165.6518 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 365.2 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 739 x 600 x 610 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 739 x 600 x 610 mmRetrieved 2026-10-01 |
| 739 x 600 x 610 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 739 x 600 x 610 mmRetrieved 2026-10-01 |
| 29.1 x 23.6 x 24.0 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 29.1 x 23.6 x 24.0 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Hose connection Ø 150 mm | — | 50 Hz · model ISO 50 Hz; (mm) unspecified | Source · OEM_SOURCE different frequency Gas inlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
| Hose connection Ø 150 mm | — | 60 Hz · model ISO 60 Hz; (mm) unspecified | Source · OEM_SOURCEGas inlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
| Hose connection Ø 150 mm | — | 60 Hz · model US 60 Hz; (mm) unspecified | Source · OEM_SOURCEGas inlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Hose connection Ø 150 mm | — | 50 Hz · model ISO 50 Hz; (mm) unspecified | Source · OEM_SOURCE different frequency Gas outlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
| Hose connection Ø 150 mm | — | 60 Hz · model ISO 60 Hz; (mm) unspecified | Source · OEM_SOURCEGas outlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
| Hose connection Ø 150 mm | — | 60 Hz · model US 60 Hz; (mm) unspecified | Source · OEM_SOURCEGas outlet (mm): Hose connection Ø 150 mmRetrieved 2026-10-01 |
Max Operating Power · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 20.0 kW kW | 20 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Max. operating power: 20.0 kWRetrieved 2026-10-01 |
| 25.2 kW kW | 25.2 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. operating power: 25.2 kWRetrieved 2026-10-01 |
| 33.8 hp hp | 25.2047 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIEDMax. operating power: 33.8 hpRetrieved 2026-10-01 |
Max. vacuum · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| -185 hPa (mbar) hPa (mbar) | -185 mbar | 50 Hz · model ISO 50 Hz; (vacuum version) unspecified | Source · OEM_SOURCE different frequency Max. differential pressure (vacuum version): -185 hPa (mbar)Retrieved 2026-10-01 |
| +130 hPa (mbar) | — | 50 Hz · model ISO 50 Hz; (overpressure version) unspecified | Source · OEM_SOURCE different frequency Max. differential pressure (overpressure version): +130 hPa (mbar)Retrieved 2026-10-01 |
| -180 hPa (mbar) hPa (mbar) | -180 mbar | 60 Hz · model ISO 60 Hz; (vacuum version) unspecified | Source · OEM_SOURCEMax. differential pressure (vacuum version): -180 hPa (mbar)Retrieved 2026-10-01 |
| +130 hPa (mbar) | — | 60 Hz · model ISO 60 Hz; (overpressure version) unspecified | Source · OEM_SOURCEMax. differential pressure (overpressure version): +130 hPa (mbar)Retrieved 2026-10-01 |
| -135 TORR TORR | -179.9847 mbar | 60 Hz · model US 60 Hz; (vacuum version) unspecified | Source · OEM_SOURCEMax. differential pressure (vacuum version): -135 TORRRetrieved 2026-10-01 |
| 97.5 TORR TORR | 129.989 mbar | 60 Hz · model US 60 Hz; (overpressure version) unspecified | Source · OEM_SOURCEMax. differential pressure (overpressure version): 97.5 TORRRetrieved 2026-10-01 |
Technology Short Name · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Side channel | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Technology short name: Side channelRetrieved 2026-10-01 |
| Side channel | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCETechnology short name: Side channelRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |