Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch SAMOS SI 2200 E1: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → SAMOS SI 1500/2200 E1 → SAMOS SI 2200 E1

Manufacturer model: SAMOS SI 2200 E1 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

32 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2200 m³/h m³/h2200 m3/h50 Hz · model
ISO 50 Hz; /volume flow
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed/volume flow: 2200 m³/h
Retrieved 2026-10-01
2640 m³/h m³/h2640 m3/h60 Hz · model
ISO 60 Hz; /volume flow
unspecified
Source · OEM_VERIFIED
Nominal pumping speed/volume flow: 2640 m³/h
Retrieved 2026-10-01
1553.6 ACFM ACFM2639.582 m3/h60 Hz · model
US 60 Hz; /volume flow
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed/volume flow: 1553.6 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 RPM RPM3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 RPM
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
82 dB(A) dB(A)82 dB(A)50 Hz · model
ISO 50 Hz; (ISO 3744)
unspecified
Source · OEM_SOURCE
different frequency
Noise level (ISO 3744): 82 dB(A)
Retrieved 2026-10-01
84 dB(A) dB(A)84 dB(A)60 Hz · model
ISO 60 Hz; (ISO 3744)
unspecified
Source · OEM_VERIFIED
Noise level (ISO 3744): 84 dB(A)
Retrieved 2026-10-01
84 dB(A) dB(A)84 dB(A)60 Hz · model
US 60 Hz; (ISO 3744)
unspecified
Source · OEM_VERIFIED
Noise level (ISO 3744): 84 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
166 kg kg166 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 166 kg
Retrieved 2026-10-01
166 kg kg166 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 166 kg
Retrieved 2026-10-01
365.2 Lbs. Lbs.165.6518 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 365.2 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
739 x 600 x 610 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 739 x 600 x 610 mm
Retrieved 2026-10-01
739 x 600 x 610 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 739 x 600 x 610 mm
Retrieved 2026-10-01
29.1 x 23.6 x 24.0 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 29.1 x 23.6 x 24.0 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
Hose connection Ø 150 mm — 50 Hz · model
ISO 50 Hz; (mm)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Hose connection Ø 150 mm — 60 Hz · model
ISO 60 Hz; (mm)
unspecified
Source · OEM_SOURCE
Gas inlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Hose connection Ø 150 mm — 60 Hz · model
US 60 Hz; (mm)
unspecified
Source · OEM_SOURCE
Gas inlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
Hose connection Ø 150 mm — 50 Hz · model
ISO 50 Hz; (mm)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Hose connection Ø 150 mm — 60 Hz · model
ISO 60 Hz; (mm)
unspecified
Source · OEM_SOURCE
Gas outlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Hose connection Ø 150 mm — 60 Hz · model
US 60 Hz; (mm)
unspecified
Source · OEM_SOURCE
Gas outlet (mm): Hose connection Ø 150 mm
Retrieved 2026-10-01
Max Operating Power · Needs review · 3 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
20.0 kW kW20 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Max. operating power: 20.0 kW
Retrieved 2026-10-01
25.2 kW kW25.2 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. operating power: 25.2 kW
Retrieved 2026-10-01
33.8 hp hp25.2047 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Max. operating power: 33.8 hp
Retrieved 2026-10-01
Max. vacuum · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
-185 hPa (mbar) hPa (mbar)-185 mbar50 Hz · model
ISO 50 Hz; (vacuum version)
unspecified
Source · OEM_SOURCE
different frequency
Max. differential pressure (vacuum version): -185 hPa (mbar)
Retrieved 2026-10-01
+130 hPa (mbar) — 50 Hz · model
ISO 50 Hz; (overpressure version)
unspecified
Source · OEM_SOURCE
different frequency
Max. differential pressure (overpressure version): +130 hPa (mbar)
Retrieved 2026-10-01
-180 hPa (mbar) hPa (mbar)-180 mbar60 Hz · model
ISO 60 Hz; (vacuum version)
unspecified
Source · OEM_SOURCE
Max. differential pressure (vacuum version): -180 hPa (mbar)
Retrieved 2026-10-01
+130 hPa (mbar) — 60 Hz · model
ISO 60 Hz; (overpressure version)
unspecified
Source · OEM_SOURCE
Max. differential pressure (overpressure version): +130 hPa (mbar)
Retrieved 2026-10-01
-135 TORR TORR-179.9847 mbar60 Hz · model
US 60 Hz; (vacuum version)
unspecified
Source · OEM_SOURCE
Max. differential pressure (vacuum version): -135 TORR
Retrieved 2026-10-01
97.5 TORR TORR129.989 mbar60 Hz · model
US 60 Hz; (overpressure version)
unspecified
Source · OEM_SOURCE
Max. differential pressure (overpressure version): 97.5 TORR
Retrieved 2026-10-01
Technology Short Name · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Side channel — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Technology short name: Side channel
Retrieved 2026-10-01
Side channel — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Technology short name: Side channel
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected