Data coverage & sources
The stored record for Chicago Pneumatic CPF270: specifications, configurations, documents, sources, and gaps.
One model, connected records
Chicago Pneumatic → Chicago Pneumatic CPF data (CPF151-480_CPVS151-340_PM_60HZ_EN) → CPF270
Manufacturer model: CPF270 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
16 stored observations · 9 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 6 observations / 2 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 607 l/s | 2185.2 m3/h | 50 Hz · model 0.7 mpa version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 607Retrieved 2026-10-03 |
| 565 l/s | 2034 m3/h | 60 Hz · model 0.8 mpa version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 565Retrieved 2026-10-03 |
| 517 l/s | 1861.2 m3/h | 60 Hz · model 1 mpa version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 517Retrieved 2026-10-03 |
| 567 l/s | 2041.2 m3/h | 50 Hz · model 0.8 mpa version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 567Retrieved 2026-10-03 |
| 517 l/s | 1861.2 m3/h | 50 Hz · model 1 mpa version, 50 Hz; FAD free air delivery | Source · OEM_SOURCE different frequency Capacity FAD: 517Retrieved 2026-10-03 |
| 605 l/s | 2178 m3/h | 60 Hz · model 0.7 mpa version, 60 Hz; FAD free air delivery | Source · OEM_SOURCECapacity FAD: 605Retrieved 2026-10-03 |
Max. pressure · Sourced · 6 observations / 2 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.7 mpa | 7000 mbar | 50 Hz · model 0.7 mpa version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 0.7Retrieved 2026-10-03 |
| 0.8 mpa | 8000 mbar | 60 Hz · model 0.8 mpa version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 0.8Retrieved 2026-10-03 |
| 0.8 mpa | 8000 mbar | 50 Hz · model 0.8 mpa version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 0.8Retrieved 2026-10-03 |
| 1 mpa | 10000 mbar | 60 Hz · model 1 mpa version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 1Retrieved 2026-10-03 |
| 0.7 mpa | 7000 mbar | 60 Hz · model 0.7 mpa version, 60 Hz unspecified | Source · OEM_SOURCEWorking pressure: 0.7Retrieved 2026-10-03 |
| 1 mpa | 10000 mbar | 50 Hz · model 1 mpa version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Working pressure: 1Retrieved 2026-10-03 |
Motor power · Sourced · 2 observations / 2 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 kW | 200 kW | 60 Hz · model 0.8 mpa version, 60 Hz unspecified | Source · OEM_SOURCEInstalled motor power: 200Retrieved 2026-10-03 |
| 200 kW | 200 kW | 50 Hz · model 0.8 mpa version, 50 Hz unspecified | Source · OEM_SOURCE different frequency Installed motor power: 200Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3240 kg | 3240 kg | Frequency not stated · model as printed: "Weight (Water cooled)" unspecified | Source · OEM_SOURCECPF270 0.8 200 270 565 1197 78 2902 x 1754 x 1980 3240 DN100Retrieved 2026-10-20 |
| 3450 kg | 3450 kg | Frequency not stated · model as printed: "Weight (Air cooled)" unspecified | Source · OEM_SOURCECPF270 0.8 200 270 565 1197 81 3502 x 1754 x 1983 3450 DN100Retrieved 2026-10-20 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|