Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Chicago Pneumatic CPI120: specifications, configurations, documents, sources, and gaps.

One model, connected records

Chicago Pneumatic → Chicago Pneumatic CPI data (CP(WW) CPI75-120 CPM75-120 CPVSM75-120 6999 6106 82_EN) → CPI120

Manufacturer model: CPI120 · OEM article / order number: Not collected · Equipment type: compressor

Technology: Rotary Screw

Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

18 stored observations · 14 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
10 bar(g)— 50 Hz · model
as printed: "Max working (CPI 75-120 50HZ)"
unspecified
Source · OEM_SOURCE
different frequency
10​ 9,5 901
Retrieved 2026-10-20
13 bar(g)— 50 Hz · model
as printed: "Max working (CPI 75-120 50HZ)"
unspecified
Source · OEM_SOURCE
different frequency
13​ 12,5 760
Retrieved 2026-10-20
8,5 bar(g)— 50 Hz · model
as printed: "Max working (CPI 75-120 50HZ)"
unspecified
Source · OEM_SOURCE
different frequency
8,5​ 8 976
Retrieved 2026-10-20
8,6 bar(g)— 60 Hz · model
as printed: "Max working (CPI 75-120 60HZ)"
unspecified
Source · OEM_SOURCE
8,6 8 951
Retrieved 2026-10-20
10,3 bar(g)— 60 Hz · model
as printed: "Max working (CPI 75-120 60HZ)"
unspecified
Source · OEM_SOURCE
10,3 9,5 872
Retrieved 2026-10-20
7,5 bar(g)— 50 Hz · model
as printed: "Max working (CPI 75-120 50HZ)"
unspecified
Source · OEM_SOURCE
different frequency
7,5​ 7 1020
Retrieved 2026-10-20
6,9 bar(g)— 60 Hz · model
as printed: "Max working (CPI 75-120 60HZ)"
unspecified
Source · OEM_SOURCE
6,9 7 1058
Retrieved 2026-10-20
12 bar(g)— 60 Hz · model
as printed: "Max working (CPI 75-120 60HZ)"
unspecified
Source · OEM_SOURCE
12 12,5 759
Retrieved 2026-10-20
Motor power · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
90 kW90 kW60 Hz · model
6,9 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Installed motor power: 90
Retrieved 2026-10-03
90 kW90 kW60 Hz · model
8,6 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Installed motor power: 90
Retrieved 2026-10-03
90 kW90 kW60 Hz · model
10,3 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Installed motor power: 90
Retrieved 2026-10-03
90 kW90 kW60 Hz · model
12 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Installed motor power: 90
Retrieved 2026-10-03
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
72 dB(A)72 dB(A)60 Hz · model
6,9 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Noise level: 72
Retrieved 2026-10-03
72 dB(A)72 dB(A)60 Hz · model
8,6 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Noise level: 72
Retrieved 2026-10-03
71 dB(A)71 dB(A)60 Hz · model
10,3 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Noise level: 71
Retrieved 2026-10-03
71 dB(A)71 dB(A)60 Hz · model
12 bar(g) version, 60 Hz
unspecified
Source · OEM_SOURCE
Noise level: 71
Retrieved 2026-10-03
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1566 kg1566 kgFrequency not stated · model
as printed: "Weight STD"
unspecified
Source · OEM_SOURCE
15336 1566 1892
Retrieved 2026-10-20
1892 kg1892 kgFrequency not stated · model
as printed: "Weight PLUS"
unspecified
Source · OEM_SOURCE
15336 1566 1892
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected