Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Elektror 1SD 510 FU/FUK: specifications, configurations, documents, sources, and gaps.

One model, connected records

Elektror → Elektror 1SD 510 FU/FUK → 1SD 510 FU/FUK

Manufacturer model: 1SD 510 FU/FUK · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

11 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5,4 m³/min324 m3/hFrequency not stated · model
FU, 80 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 5,4
Retrieved 2026-10-06
5,20 m³/min312 m3/hFrequency not stated · model
FU, 80 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 5,20
Retrieved 2026-10-06
5,4 m³/min324 m3/hFrequency not stated · model
FUK, 80 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 5,4
Retrieved 2026-10-06
5,20 m³/min312 m3/hFrequency not stated · model
FUK, 80 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 5,20
Retrieved 2026-10-06
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
30 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
4610 30 84
Retrieved 2026-10-20
28 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
4610 28 84
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
30000 Pa300 mbarFrequency not stated · model
FU, 80 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 30000
Retrieved 2026-10-06
30000 Pa300 mbarFrequency not stated · model
FUK, 80 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 30000
Retrieved 2026-10-06
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
30000 Pa300 mbarFrequency not stated · model
FU, 80 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 30000
Retrieved 2026-10-06
30000 Pa300 mbarFrequency not stated · model
FUK, 80 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 30000
Retrieved 2026-10-06
Power consumption · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3,8 — Frequency not stated · model
as printed: "Performance"
unspecified
Source · OEM_SOURCE
3,8
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified80