Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Elektror 1SD 710 - 50/4,0: specifications, configurations, documents, sources, and gaps.

One model, connected records

Elektror → Elektror 1SD 710 → 1SD 710 - 50/4,0

Manufacturer model: 1SD 710 - 50/4,0 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

22 stored observations · 12 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5,3 m³/min318 m3/h50 Hz · model
50 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 5,3
Retrieved 2026-10-06
5,3 m³/min318 m3/h50 Hz · model
50 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 5,3
Retrieved 2026-10-06
6,27 m³/min376.2 m3/h60 Hz · model
60 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 6,27
Retrieved 2026-10-06
6,27 m³/min376.2 m3/h60 Hz · model
60 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 6,27
Retrieved 2026-10-06
5,30 m³/min318 m3/h50 Hz · model
50 Hz IE3; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 5,30
Retrieved 2026-10-06
5,30 m³/min318 m3/h50 Hz · model
50 Hz IE3; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 5,30
Retrieved 2026-10-06
6,27 m³/min376.2 m3/h60 Hz · model
60 Hz IE3; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 6,27
Retrieved 2026-10-06
6,27 m³/min376.2 m3/h60 Hz · model
60 Hz IE3; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 6,27
Retrieved 2026-10-06
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4,0 kW4 kW50 Hz · model
50 Hz; printed as Performance
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 4,0
Retrieved 2026-10-06
6,0 kW6 kW60 Hz · model
60 Hz; printed as Performance
unspecified
Source · OEM_SOURCE
Motor power: 6,0
Retrieved 2026-10-06
4,00 kW4 kW50 Hz · model
50 Hz IE3; printed as Performance
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 4,00
Retrieved 2026-10-06
4,60 kW4.6 kW60 Hz · model
60 Hz IE3; printed as Performance
unspecified
Source · OEM_SOURCE
Motor power: 4,60
Retrieved 2026-10-06
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
63 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
4,00 63 69
Retrieved 2026-10-20
42 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
4,0 42 69
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
33000 Pa330 mbar50 Hz · model
50 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 33000
Retrieved 2026-10-06
33000 Pa330 mbar60 Hz · model
60 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 33000
Retrieved 2026-10-06
35000 Pa350 mbar50 Hz · model
50 Hz IE3; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 35000
Retrieved 2026-10-06
36000 Pa360 mbar60 Hz · model
60 Hz IE3; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 36000
Retrieved 2026-10-06
Max. vacuum · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
29000 Pa290 mbar50 Hz · model
50 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 29000
Retrieved 2026-10-06
33000 Pa330 mbar60 Hz · model
60 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 33000
Retrieved 2026-10-06
29000 Pa290 mbar50 Hz · model
50 Hz IE3; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 29000
Retrieved 2026-10-06
33000 Pa330 mbar60 Hz · model
60 Hz IE3; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 33000
Retrieved 2026-10-06

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified70