Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Elektror 1SD 910 - 50/11,0: specifications, configurations, documents, sources, and gaps.

One model, connected records

Elektror → Elektror 1SD 910 → 1SD 910 - 50/11,0

Manufacturer model: 1SD 910 - 50/11,0 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

11 stored observations · 6 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
17,50 m³/min1050 m3/h50 Hz · model
50 Hz IE3; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 17,50
Retrieved 2026-10-06
17,50 m³/min1050 m3/h50 Hz · model
50 Hz IE3; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 17,50
Retrieved 2026-10-06
20,80 m³/min1248 m3/h60 Hz · model
60 Hz IE3; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 20,80
Retrieved 2026-10-06
20,80 m³/min1248 m3/h60 Hz · model
60 Hz IE3; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 20,80
Retrieved 2026-10-06
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11,0 kW11 kW50 Hz · model
50 Hz IE3; printed as Performance
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 11,0
Retrieved 2026-10-06
12,60 kW12.6 kW60 Hz · model
60 Hz IE3; printed as Performance
unspecified
Source · OEM_SOURCE
Motor power: 12,60
Retrieved 2026-10-06
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
140 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
11,0 140 75
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
28000 Pa280 mbar50 Hz · model
50 Hz IE3; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 28000
Retrieved 2026-10-06
26000 Pa260 mbar60 Hz · model
60 Hz IE3; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 26000
Retrieved 2026-10-06
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
29000 Pa290 mbar50 Hz · model
50 Hz IE3; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 29000
Retrieved 2026-10-06
27000 Pa270 mbar60 Hz · model
60 Hz IE3; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 27000
Retrieved 2026-10-06

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected