Data coverage & sources
The stored record for Elmo Rietschle V-VC 1100: specifications, configurations, documents, sources, and gaps.
One model, connected records
Elmo Rietschle → Elmo Rietschle data sheet V-VC 400-900 (V-VC) → V-VC 1100
Manufacturer model: V-VC 1100 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Oil-Lubricated Rotary Vane
Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
15 stored observations · 9 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1100 m3/h | 1100 m3/h | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal suction capacity: 1100Retrieved 2026-10-06 |
| 1320 m3/h | 1320 m3/h | 60 Hz · model 60 Hz unspecified | Source · OEM_SOURCENominal suction capacity: 1320Retrieved 2026-10-06 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0,1 mbar (abs.) | 0.1 mbar | Frequency not stated · series as printed: "Endpartialdruck / Ultimate partial pressure"; one cell shared by several models unspecified | Source · OEM_SOURCE0,1Retrieved 2026-10-20 |
| 1,0 mbar (abs.) | 1 mbar | Frequency not stated · model as printed: "Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast)" unspecified | Source · OEM_SOURCE1,0Retrieved 2026-10-20 |
| 20 * * mbar (abs.) | — | Frequency not stated · model as printed: "Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast)" unspecified | Source · OEM_SOURCE20 *Retrieved 2026-10-20 |
Motor power · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 36 kW | 36 kW | 60 Hz · model as printed: "Motorleistung / Motor rating 60 Hz (* Grobvakuum / Coarse vacuum)" unspecified | Source · OEM_SOURCE26,0 36 *Retrieved 2026-10-20 |
| 22,0 kW | 22 kW | 50 Hz · model as printed: "Motorleistung / Motor rating 50 Hz" unspecified | Source · OEM_SOURCE different frequency 50 Hz 22,0Retrieved 2026-10-20 |
| 30 kW | 30 kW | 50 Hz · model as printed: "Motorleistung / Motor rating 50 Hz (* Grobvakuum / Coarse vacuum)" unspecified | Source · OEM_SOURCE different frequency 22,0 30 *Retrieved 2026-10-20 |
| 26,0 kW | 26 kW | 60 Hz · model as printed: "Motorleistung / Motor rating 60 Hz" unspecified | Source · OEM_SOURCE60 Hz 26,0Retrieved 2026-10-20 |
Speed · Sourced · 2 observations / 1 sources
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1065 kg | 1065 kg | 60 Hz · model as printed: "Max. Gewicht / Max. weight 60 Hz" unspecified | Source · OEM_SOURCE60 Hz 1065 1235 1125 1260Retrieved 2026-10-20 |
| 1055 kg | 1055 kg | 50 Hz · model as printed: "Max. Gewicht / Max. weight 50 Hz" unspecified | Source · OEM_SOURCE different frequency 50 Hz 1055 1250 1125 1260Retrieved 2026-10-20 |
| 1235 kg | 1235 kg | 60 Hz · model as printed: "Max. Gewicht / Max. weight 60 Hz (coarse vacuum *)" unspecified | Source · OEM_SOURCE60 Hz 1065 1235 1125 1260Retrieved 2026-10-20 |
| 1250 kg | 1250 kg | 50 Hz · model as printed: "Max. Gewicht / Max. weight 50 Hz (coarse vacuum *)" unspecified | Source · OEM_SOURCE different frequency 50 Hz 1055 1250 1125 1260Retrieved 2026-10-20 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 | |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |