One model, connected records

Elmo Rietschle → Elmo Rietschle data sheet V-VC 400-900 (V-VC) → V-VC 1100

Manufacturer model: V-VC 1100 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Oil-Lubricated Rotary Vane

Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

15 stored observations · 9 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1100 m3/h1100 m3/h50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal suction capacity: 1100
Retrieved 2026-10-06
1320 m3/h1320 m3/h60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Nominal suction capacity: 1320
Retrieved 2026-10-06
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0,1 mbar (abs.)0.1 mbarFrequency not stated · series
as printed: "Endpartialdruck / Ultimate partial pressure"; one cell shared by several models
unspecified
Source · OEM_SOURCE
0,1
Retrieved 2026-10-20
1,0 mbar (abs.)1 mbarFrequency not stated · model
as printed: "Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast)"
unspecified
Source · OEM_SOURCE
1,0
Retrieved 2026-10-20
20 * * mbar (abs.)— Frequency not stated · model
as printed: "Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast)"
unspecified
Source · OEM_SOURCE
20 *
Retrieved 2026-10-20
Motor power · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
36 kW36 kW60 Hz · model
as printed: "Motorleistung / Motor rating 60 Hz (* Grobvakuum / Coarse vacuum)"
unspecified
Source · OEM_SOURCE
26,0 36 *
Retrieved 2026-10-20
22,0 kW22 kW50 Hz · model
as printed: "Motorleistung / Motor rating 50 Hz"
unspecified
Source · OEM_SOURCE
different frequency
50 Hz 22,0
Retrieved 2026-10-20
30 kW30 kW50 Hz · model
as printed: "Motorleistung / Motor rating 50 Hz (* Grobvakuum / Coarse vacuum)"
unspecified
Source · OEM_SOURCE
different frequency
22,0 30 *
Retrieved 2026-10-20
26,0 kW26 kW60 Hz · model
as printed: "Motorleistung / Motor rating 60 Hz"
unspecified
Source · OEM_SOURCE
60 Hz 26,0
Retrieved 2026-10-20
Speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
950 min-1950 rpm50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Speed: 950
Retrieved 2026-10-06
1150 min-11150 rpm60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Speed: 1150
Retrieved 2026-10-06
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1065 kg1065 kg60 Hz · model
as printed: "Max. Gewicht / Max. weight 60 Hz"
unspecified
Source · OEM_SOURCE
60 Hz 1065 1235 1125 1260
Retrieved 2026-10-20
1055 kg1055 kg50 Hz · model
as printed: "Max. Gewicht / Max. weight 50 Hz"
unspecified
Source · OEM_SOURCE
different frequency
50 Hz 1055 1250 1125 1260
Retrieved 2026-10-20
1235 kg1235 kg60 Hz · model
as printed: "Max. Gewicht / Max. weight 60 Hz (coarse vacuum *)"
unspecified
Source · OEM_SOURCE
60 Hz 1065 1235 1125 1260
Retrieved 2026-10-20
1250 kg1250 kg50 Hz · model
as printed: "Max. Gewicht / Max. weight 50 Hz (coarse vacuum *)"
unspecified
Source · OEM_SOURCE
different frequency
50 Hz 1055 1250 1125 1260
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected