Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e08 TD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e08 TD

Manufacturer model: e08 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

55 stored observations · 27 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 43 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
577 m³/h577 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 577
Retrieved 2026-10-05
554 m³/h554 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 554
Retrieved 2026-10-05
532 m³/h532 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 532
Retrieved 2026-10-05
510 m³/h510 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 510
Retrieved 2026-10-05
489 m³/h489 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 489
Retrieved 2026-10-05
468 m³/h468 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 468
Retrieved 2026-10-05
447 m³/h447 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 447
Retrieved 2026-10-05
428 m³/h428 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 428
Retrieved 2026-10-05
408 m³/h408 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 408
Retrieved 2026-10-05
389 m³/h389 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 389
Retrieved 2026-10-05
371 m³/h371 m3/h50 Hz · model
50 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 371
Retrieved 2026-10-05
353 m³/h353 m3/h50 Hz · model
50 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 353
Retrieved 2026-10-05
336 m³/h336 m3/h50 Hz · model
50 Hz; compression; at +600 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 336
Retrieved 2026-10-05
577 m³/h577 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 577
Retrieved 2026-10-05
555 m³/h555 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 555
Retrieved 2026-10-05
528 m³/h528 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 528
Retrieved 2026-10-05
500 m³/h500 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 500
Retrieved 2026-10-05
470 m³/h470 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 470
Retrieved 2026-10-05
439 m³/h439 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 439
Retrieved 2026-10-05
406 m³/h406 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 406
Retrieved 2026-10-05
372 m³/h372 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 372
Retrieved 2026-10-05
337 m³/h337 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 337
Retrieved 2026-10-05
696 m³/h696 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 696
Retrieved 2026-10-05
677 m³/h677 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 677
Retrieved 2026-10-05
657 m³/h657 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 657
Retrieved 2026-10-05
638 m³/h638 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 638
Retrieved 2026-10-05
619 m³/h619 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 619
Retrieved 2026-10-05
601 m³/h601 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 601
Retrieved 2026-10-05
583 m³/h583 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 583
Retrieved 2026-10-05
565 m³/h565 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 565
Retrieved 2026-10-05
547 m³/h547 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 547
Retrieved 2026-10-05
530 m³/h530 m3/h60 Hz · model
60 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 530
Retrieved 2026-10-05
513 m³/h513 m3/h60 Hz · model
60 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 513
Retrieved 2026-10-05
496 m³/h496 m3/h60 Hz · model
60 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 496
Retrieved 2026-10-05
696 m³/h696 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 696
Retrieved 2026-10-05
677 m³/h677 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 677
Retrieved 2026-10-05
651 m³/h651 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 651
Retrieved 2026-10-05
625 m³/h625 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 625
Retrieved 2026-10-05
597 m³/h597 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 597
Retrieved 2026-10-05
569 m³/h569 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 569
Retrieved 2026-10-05
539 m³/h539 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 539
Retrieved 2026-10-05
509 m³/h509 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 509
Retrieved 2026-10-05
477 m³/h477 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 477
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
7.50 kW7.5 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; compression; at Δp max 600 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at Δp max 550 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
11.00 kW11 kW60 Hz · model
60 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 11.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
600 mbar600 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 600
Retrieved 2026-10-05
550 mbar550 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 550
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 400
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 400
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10