Data coverage & sources
The stored record for FPZ e08 TD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e08 TD
Manufacturer model: e08 TD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
55 stored observations · 27 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 43 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 577 m³/h | 577 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 577Retrieved 2026-10-05 |
| 554 m³/h | 554 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 554Retrieved 2026-10-05 |
| 532 m³/h | 532 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 532Retrieved 2026-10-05 |
| 510 m³/h | 510 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 510Retrieved 2026-10-05 |
| 489 m³/h | 489 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 489Retrieved 2026-10-05 |
| 468 m³/h | 468 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 468Retrieved 2026-10-05 |
| 447 m³/h | 447 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 447Retrieved 2026-10-05 |
| 428 m³/h | 428 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 428Retrieved 2026-10-05 |
| 408 m³/h | 408 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 408Retrieved 2026-10-05 |
| 389 m³/h | 389 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 389Retrieved 2026-10-05 |
| 371 m³/h | 371 m3/h | 50 Hz · model 50 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 371Retrieved 2026-10-05 |
| 353 m³/h | 353 m3/h | 50 Hz · model 50 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 353Retrieved 2026-10-05 |
| 336 m³/h | 336 m3/h | 50 Hz · model 50 Hz; compression; at +600 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 336Retrieved 2026-10-05 |
| 577 m³/h | 577 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 577Retrieved 2026-10-05 |
| 555 m³/h | 555 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 555Retrieved 2026-10-05 |
| 528 m³/h | 528 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 528Retrieved 2026-10-05 |
| 500 m³/h | 500 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 500Retrieved 2026-10-05 |
| 470 m³/h | 470 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 470Retrieved 2026-10-05 |
| 439 m³/h | 439 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 439Retrieved 2026-10-05 |
| 406 m³/h | 406 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 406Retrieved 2026-10-05 |
| 372 m³/h | 372 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 372Retrieved 2026-10-05 |
| 337 m³/h | 337 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 337Retrieved 2026-10-05 |
| 696 m³/h | 696 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 696Retrieved 2026-10-05 |
| 677 m³/h | 677 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 677Retrieved 2026-10-05 |
| 657 m³/h | 657 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 657Retrieved 2026-10-05 |
| 638 m³/h | 638 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 638Retrieved 2026-10-05 |
| 619 m³/h | 619 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 619Retrieved 2026-10-05 |
| 601 m³/h | 601 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 601Retrieved 2026-10-05 |
| 583 m³/h | 583 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 583Retrieved 2026-10-05 |
| 565 m³/h | 565 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 565Retrieved 2026-10-05 |
| 547 m³/h | 547 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 547Retrieved 2026-10-05 |
| 530 m³/h | 530 m3/h | 60 Hz · model 60 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 530Retrieved 2026-10-05 |
| 513 m³/h | 513 m3/h | 60 Hz · model 60 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 513Retrieved 2026-10-05 |
| 496 m³/h | 496 m3/h | 60 Hz · model 60 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 496Retrieved 2026-10-05 |
| 696 m³/h | 696 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 696Retrieved 2026-10-05 |
| 677 m³/h | 677 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 677Retrieved 2026-10-05 |
| 651 m³/h | 651 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 651Retrieved 2026-10-05 |
| 625 m³/h | 625 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 625Retrieved 2026-10-05 |
| 597 m³/h | 597 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 597Retrieved 2026-10-05 |
| 569 m³/h | 569 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 569Retrieved 2026-10-05 |
| 539 m³/h | 539 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 539Retrieved 2026-10-05 |
| 509 m³/h | 509 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 509Retrieved 2026-10-05 |
| 477 m³/h | 477 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 477Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at Δp max 600 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; compression; at Δp max 550 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 7.50Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 600 mbar | 600 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 600Retrieved 2026-10-05 |
| 550 mbar | 550 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 550Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 mbar | 400 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 400Retrieved 2026-10-05 |
| 400 mbar | 400 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 400Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |