Specifications and evidence

47 stored observations · 23 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 35 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
944 m³/h944 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 944
Retrieved 2026-10-05
895 m³/h895 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 895
Retrieved 2026-10-05
847 m³/h847 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 847
Retrieved 2026-10-05
799 m³/h799 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 799
Retrieved 2026-10-05
752 m³/h752 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 752
Retrieved 2026-10-05
706 m³/h706 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 706
Retrieved 2026-10-05
660 m³/h660 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 660
Retrieved 2026-10-05
615 m³/h615 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 615
Retrieved 2026-10-05
571 m³/h571 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 571
Retrieved 2026-10-05
528 m³/h528 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 528
Retrieved 2026-10-05
944 m³/h944 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 944
Retrieved 2026-10-05
892 m³/h892 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 892
Retrieved 2026-10-05
841 m³/h841 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 841
Retrieved 2026-10-05
782 m³/h782 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 782
Retrieved 2026-10-05
715 m³/h715 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 715
Retrieved 2026-10-05
640 m³/h640 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 640
Retrieved 2026-10-05
557 m³/h557 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 557
Retrieved 2026-10-05
466 m³/h466 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 466
Retrieved 2026-10-05
1140 m³/h1140 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 1140
Retrieved 2026-10-05
1097 m³/h1097 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1097
Retrieved 2026-10-05
1055 m³/h1055 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1055
Retrieved 2026-10-05
1014 m³/h1014 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1014
Retrieved 2026-10-05
973 m³/h973 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 973
Retrieved 2026-10-05
932 m³/h932 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 932
Retrieved 2026-10-05
892 m³/h892 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 892
Retrieved 2026-10-05
852 m³/h852 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 852
Retrieved 2026-10-05
813 m³/h813 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 813
Retrieved 2026-10-05
1140 m³/h1140 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 1140
Retrieved 2026-10-05
1088 m³/h1088 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1088
Retrieved 2026-10-05
1042 m³/h1042 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1042
Retrieved 2026-10-05
990 m³/h990 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 990
Retrieved 2026-10-05
931 m³/h931 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 931
Retrieved 2026-10-05
867 m³/h867 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 867
Retrieved 2026-10-05
797 m³/h797 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 797
Retrieved 2026-10-05
720 m³/h720 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 720
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
7.50 kW7.5 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
18.50 kW18.5 kW50 Hz · model
50 Hz; compression; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
7.50 kW7.5 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at Δp max 350 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; compression; at Δp max 425 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 18.50
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; vacuum; at Δp max 350 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 450
Retrieved 2026-10-05
425 mbar425 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 425
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
350 mbar350 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 350
Retrieved 2026-10-05
350 mbar350 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 350
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected