Data coverage & sources
The stored record for FPZ e12 MD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e12 MD
Manufacturer model: e12 MD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
57 stored observations · 28 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 45 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 521 m³/h | 521 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 521Retrieved 2026-10-05 |
| 500 m³/h | 500 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 500Retrieved 2026-10-05 |
| 479 m³/h | 479 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 479Retrieved 2026-10-05 |
| 459 m³/h | 459 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 459Retrieved 2026-10-05 |
| 439 m³/h | 439 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 439Retrieved 2026-10-05 |
| 419 m³/h | 419 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 419Retrieved 2026-10-05 |
| 400 m³/h | 400 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 400Retrieved 2026-10-05 |
| 381 m³/h | 381 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 381Retrieved 2026-10-05 |
| 362 m³/h | 362 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 362Retrieved 2026-10-05 |
| 344 m³/h | 344 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 344Retrieved 2026-10-05 |
| 326 m³/h | 326 m3/h | 50 Hz · model 50 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 326Retrieved 2026-10-05 |
| 308 m³/h | 308 m3/h | 50 Hz · model 50 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 308Retrieved 2026-10-05 |
| 291 m³/h | 291 m3/h | 50 Hz · model 50 Hz; compression; at +600 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 291Retrieved 2026-10-05 |
| 274 m³/h | 274 m3/h | 50 Hz · model 50 Hz; compression; at +650 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 274Retrieved 2026-10-05 |
| 521 m³/h | 521 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 521Retrieved 2026-10-05 |
| 498 m³/h | 498 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 498Retrieved 2026-10-05 |
| 474 m³/h | 474 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 474Retrieved 2026-10-05 |
| 448 m³/h | 448 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 448Retrieved 2026-10-05 |
| 419 m³/h | 419 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 419Retrieved 2026-10-05 |
| 388 m³/h | 388 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 388Retrieved 2026-10-05 |
| 354 m³/h | 354 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 354Retrieved 2026-10-05 |
| 318 m³/h | 318 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 318Retrieved 2026-10-05 |
| 279 m³/h | 279 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 279Retrieved 2026-10-05 |
| 629 m³/h | 629 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 629Retrieved 2026-10-05 |
| 611 m³/h | 611 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 611Retrieved 2026-10-05 |
| 593 m³/h | 593 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 593Retrieved 2026-10-05 |
| 575 m³/h | 575 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 575Retrieved 2026-10-05 |
| 557 m³/h | 557 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 557Retrieved 2026-10-05 |
| 540 m³/h | 540 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 540Retrieved 2026-10-05 |
| 523 m³/h | 523 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 523Retrieved 2026-10-05 |
| 506 m³/h | 506 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 506Retrieved 2026-10-05 |
| 489 m³/h | 489 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 489Retrieved 2026-10-05 |
| 473 m³/h | 473 m3/h | 60 Hz · model 60 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 473Retrieved 2026-10-05 |
| 456 m³/h | 456 m3/h | 60 Hz · model 60 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 456Retrieved 2026-10-05 |
| 440 m³/h | 440 m3/h | 60 Hz · model 60 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 440Retrieved 2026-10-05 |
| 425 m³/h | 425 m3/h | 60 Hz · model 60 Hz; compression; at +600 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 425Retrieved 2026-10-05 |
| 629 m³/h | 629 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 629Retrieved 2026-10-05 |
| 606 m³/h | 606 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 606Retrieved 2026-10-05 |
| 585 m³/h | 585 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 585Retrieved 2026-10-05 |
| 561 m³/h | 561 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 561Retrieved 2026-10-05 |
| 535 m³/h | 535 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 535Retrieved 2026-10-05 |
| 508 m³/h | 508 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 508Retrieved 2026-10-05 |
| 478 m³/h | 478 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 478Retrieved 2026-10-05 |
| 447 m³/h | 447 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 447Retrieved 2026-10-05 |
| 414 m³/h | 414 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 414Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at Δp max 650 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; compression; at Δp max 600 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 650 mbar | 650 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 650Retrieved 2026-10-05 |
| 600 mbar | 600 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 600Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 mbar | 400 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 400Retrieved 2026-10-05 |
| 400 mbar | 400 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 400Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |