Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e12 MD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e12 MD

Manufacturer model: e12 MD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

57 stored observations · 28 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 45 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
521 m³/h521 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 521
Retrieved 2026-10-05
500 m³/h500 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 500
Retrieved 2026-10-05
479 m³/h479 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 479
Retrieved 2026-10-05
459 m³/h459 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 459
Retrieved 2026-10-05
439 m³/h439 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 439
Retrieved 2026-10-05
419 m³/h419 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 419
Retrieved 2026-10-05
400 m³/h400 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 400
Retrieved 2026-10-05
381 m³/h381 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 381
Retrieved 2026-10-05
362 m³/h362 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 362
Retrieved 2026-10-05
344 m³/h344 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 344
Retrieved 2026-10-05
326 m³/h326 m3/h50 Hz · model
50 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 326
Retrieved 2026-10-05
308 m³/h308 m3/h50 Hz · model
50 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 308
Retrieved 2026-10-05
291 m³/h291 m3/h50 Hz · model
50 Hz; compression; at +600 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 291
Retrieved 2026-10-05
274 m³/h274 m3/h50 Hz · model
50 Hz; compression; at +650 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 274
Retrieved 2026-10-05
521 m³/h521 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 521
Retrieved 2026-10-05
498 m³/h498 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 498
Retrieved 2026-10-05
474 m³/h474 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 474
Retrieved 2026-10-05
448 m³/h448 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 448
Retrieved 2026-10-05
419 m³/h419 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 419
Retrieved 2026-10-05
388 m³/h388 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 388
Retrieved 2026-10-05
354 m³/h354 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 354
Retrieved 2026-10-05
318 m³/h318 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 318
Retrieved 2026-10-05
279 m³/h279 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 279
Retrieved 2026-10-05
629 m³/h629 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 629
Retrieved 2026-10-05
611 m³/h611 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 611
Retrieved 2026-10-05
593 m³/h593 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 593
Retrieved 2026-10-05
575 m³/h575 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 575
Retrieved 2026-10-05
557 m³/h557 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 557
Retrieved 2026-10-05
540 m³/h540 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 540
Retrieved 2026-10-05
523 m³/h523 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 523
Retrieved 2026-10-05
506 m³/h506 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 506
Retrieved 2026-10-05
489 m³/h489 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 489
Retrieved 2026-10-05
473 m³/h473 m3/h60 Hz · model
60 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 473
Retrieved 2026-10-05
456 m³/h456 m3/h60 Hz · model
60 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 456
Retrieved 2026-10-05
440 m³/h440 m3/h60 Hz · model
60 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 440
Retrieved 2026-10-05
425 m³/h425 m3/h60 Hz · model
60 Hz; compression; at +600 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 425
Retrieved 2026-10-05
629 m³/h629 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 629
Retrieved 2026-10-05
606 m³/h606 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 606
Retrieved 2026-10-05
585 m³/h585 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 585
Retrieved 2026-10-05
561 m³/h561 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 561
Retrieved 2026-10-05
535 m³/h535 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 535
Retrieved 2026-10-05
508 m³/h508 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 508
Retrieved 2026-10-05
478 m³/h478 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 478
Retrieved 2026-10-05
447 m³/h447 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 447
Retrieved 2026-10-05
414 m³/h414 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 414
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9.20 kW9.2 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; compression; at Δp max 650 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at Δp max 600 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
11.00 kW11 kW60 Hz · model
60 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 11.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
650 mbar650 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 650
Retrieved 2026-10-05
600 mbar600 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 600
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 400
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 400
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected