Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ K04 TD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → K04 TD

Manufacturer model: K04 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

32 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 23 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
139.0 m³/h139 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 139.0
Retrieved 2026-10-05
127.6 m³/h127.6 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 127.6
Retrieved 2026-10-05
116.3 m³/h116.3 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 116.3
Retrieved 2026-10-05
104.9 m³/h104.9 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 104.9
Retrieved 2026-10-05
93.6 m³/h93.6 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 93.6
Retrieved 2026-10-05
82.4 m³/h82.4 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 82.4
Retrieved 2026-10-05
71.1 m³/h71.1 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 71.1
Retrieved 2026-10-05
59.9 m³/h59.9 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 59.9
Retrieved 2026-10-05
48.7 m³/h48.7 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 48.7
Retrieved 2026-10-05
139.0 m³/h139 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 139.0
Retrieved 2026-10-05
127.6 m³/h127.6 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 127.6
Retrieved 2026-10-05
114.5 m³/h114.5 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 114.5
Retrieved 2026-10-05
99.6 m³/h99.6 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 99.6
Retrieved 2026-10-05
82.9 m³/h82.9 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 82.9
Retrieved 2026-10-05
64.5 m³/h64.5 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 64.5
Retrieved 2026-10-05
168.0 m³/h168 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 168.0
Retrieved 2026-10-05
158.7 m³/h158.7 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 158.7
Retrieved 2026-10-05
149.4 m³/h149.4 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 149.4
Retrieved 2026-10-05
140.1 m³/h140.1 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 140.1
Retrieved 2026-10-05
130.7 m³/h130.7 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 130.7
Retrieved 2026-10-05
121.4 m³/h121.4 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 121.4
Retrieved 2026-10-05
112.1 m³/h112.1 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 112.1
Retrieved 2026-10-05
102.7 m³/h102.7 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 102.7
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2.20 kW2.2 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 2.20
Retrieved 2026-10-05
2.20 kW2.2 kW50 Hz · model
50 Hz; compression; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 2.20
Retrieved 2026-10-05
2.20 kW2.2 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 2.20
Retrieved 2026-10-05
2.20 kW2.2 kW50 Hz · model
50 Hz; vacuum; at Δp max 275 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 2.20
Retrieved 2026-10-05
2.60 kW2.6 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 2.60
Retrieved 2026-10-05
2.60 kW2.6 kW60 Hz · model
60 Hz; compression; at Δp max 350 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 2.60
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 400
Retrieved 2026-10-05
350 mbar350 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 350
Retrieved 2026-10-05
Max. vacuum · Other conditions · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
275 mbar275 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 275
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected