Data coverage & sources
The stored record for FPZ K06 TS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → K06 TS
Manufacturer model: K06 TS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
37 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 25 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 562.0 m³/h | 562 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 562.0Retrieved 2026-10-05 |
| 506.3 m³/h | 506.3 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 506.3Retrieved 2026-10-05 |
| 450.7 m³/h | 450.7 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 450.7Retrieved 2026-10-05 |
| 395.0 m³/h | 395 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 395.0Retrieved 2026-10-05 |
| 339.4 m³/h | 339.4 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 339.4Retrieved 2026-10-05 |
| 283.8 m³/h | 283.8 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 283.8Retrieved 2026-10-05 |
| 228.2 m³/h | 228.2 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 228.2Retrieved 2026-10-05 |
| 562.0 m³/h | 562 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 562.0Retrieved 2026-10-05 |
| 505.3 m³/h | 505.3 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 505.3Retrieved 2026-10-05 |
| 440.3 m³/h | 440.3 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 440.3Retrieved 2026-10-05 |
| 366.9 m³/h | 366.9 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 366.9Retrieved 2026-10-05 |
| 285.2 m³/h | 285.2 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 285.2Retrieved 2026-10-05 |
| 195.0 m³/h | 195 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 195.0Retrieved 2026-10-05 |
| 679.0 m³/h | 679 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 679.0Retrieved 2026-10-05 |
| 633.1 m³/h | 633.1 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 633.1Retrieved 2026-10-05 |
| 587.0 m³/h | 587 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 587.0Retrieved 2026-10-05 |
| 540.8 m³/h | 540.8 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 540.8Retrieved 2026-10-05 |
| 494.5 m³/h | 494.5 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 494.5Retrieved 2026-10-05 |
| 448.0 m³/h | 448 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 448.0Retrieved 2026-10-05 |
| 679.0 m³/h | 679 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 679.0Retrieved 2026-10-05 |
| 632.0 m³/h | 632 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 632.0Retrieved 2026-10-05 |
| 578.1 m³/h | 578.1 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 578.1Retrieved 2026-10-05 |
| 517.3 m³/h | 517.3 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 517.3Retrieved 2026-10-05 |
| 449.5 m³/h | 449.5 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 449.5Retrieved 2026-10-05 |
| 374.9 m³/h | 374.9 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 374.9Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 4.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; compression; at Δp max 300 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 4.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 250 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 4.80 kW | 4.8 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 4.80Retrieved 2026-10-05 |
| 9.00 kW | 9 kW | 60 Hz · model 60 Hz; compression; at Δp max 275 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 9.00Retrieved 2026-10-05 |
| 4.80 kW | 4.8 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 4.80Retrieved 2026-10-05 |
| 9.00 kW | 9 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 250 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 9.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 300 mbar | 300 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 300Retrieved 2026-10-05 |
| 275 mbar | 275 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 275Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 250 mbar | 250 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 250Retrieved 2026-10-05 |
| 250 mbar | 250 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 250Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |