Data coverage & sources
The stored record for Friulair LF * 023: specifications, configurations, documents, sources, and gaps.
One model, connected records
Friulair → Friulair LF Series Filters for Reliable Compressed Air Filtration → LF * 023
Manufacturer model: LF * 023 · OEM article / order number: Not collected · Equipment type: filter
Technology: Filtration / Air Treatment
Related applications: Food-Contact Air, Instrument Air, Plant Air, Spray + Finishing
Related industries: General Manufacturing, Pharmaceutical
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
2 stored observations · 2 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Rated capacity · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 138 Nm³/h | 138 m3/h | Frequency not stated · model Conditions not stated normal | Source · OEM_SOURCEFlow rate: 138Retrieved 2026-10-04 |
Max. working pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 16 barg | 16000 mbar | Frequency not stated · series as printed: "Maximum Working Conditions – Inlet air pressure"; one cell shared by several models unspecified | Source · OEM_SOURCEInlet air pressure: 16 barg (LF*006÷045), 14 barg(LF*061) and 11 barg (LF*100)Retrieved 2026-10-20 |
Pressure drop · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|