Data coverage & sources
The stored record for FS-Curtis NXB08: specifications, configurations, documents, sources, and gaps.
One model, connected records
FS-Curtis → FS-Curtis NX Series 4-15kW / 5-20HP → NXB08
Manufacturer model: NXB08 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
32 stored observations · 32 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 16 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 45 CFM | 76.4555 m3/h | Frequency not stated · model Configuration: Tank Mount; FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 45Retrieved 2026-10-05 |
| 42 CFM | 71.3584 m3/h | Frequency not stated · model Configuration: Tank Mount; FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 42Retrieved 2026-10-05 |
| 37 CFM | 62.8634 m3/h | Frequency not stated · model Configuration: Tank Mount; FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 37Retrieved 2026-10-05 |
| 33 CFM | 56.0673 m3/h | Frequency not stated · model Configuration: Tank Mount; FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 33Retrieved 2026-10-05 |
| 45 CFM | 76.4555 m3/h | Frequency not stated · model Configuration: UltraPack; FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 45Retrieved 2026-10-05 |
| 42 CFM | 71.3584 m3/h | Frequency not stated · model Configuration: UltraPack; FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 42Retrieved 2026-10-05 |
| 37 CFM | 62.8634 m3/h | Frequency not stated · model Configuration: UltraPack; FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 37Retrieved 2026-10-05 |
| 33 CFM | 56.0673 m3/h | Frequency not stated · model Configuration: UltraPack; FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 33Retrieved 2026-10-05 |
| 45 CFM | 76.4555 m3/h | Frequency not stated · model Configuration: Base Mount; FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 45Retrieved 2026-10-05 |
| 42 CFM | 71.3584 m3/h | Frequency not stated · model Configuration: Base Mount; FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 42Retrieved 2026-10-05 |
| 37 CFM | 62.8634 m3/h | Frequency not stated · model Configuration: Base Mount; FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 37Retrieved 2026-10-05 |
| 33 CFM | 56.0673 m3/h | Frequency not stated · model Configuration: Base Mount; FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 33Retrieved 2026-10-05 |
| 45 CFM | 76.4555 m3/h | Frequency not stated · model Configuration: Base Mount w/ Dryer; FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 45Retrieved 2026-10-05 |
| 42 CFM | 71.3584 m3/h | Frequency not stated · model Configuration: Base Mount w/ Dryer; FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 42Retrieved 2026-10-05 |
| 37 CFM | 62.8634 m3/h | Frequency not stated · model Configuration: Base Mount w/ Dryer; FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 37Retrieved 2026-10-05 |
| 33 CFM | 56.0673 m3/h | Frequency not stated · model Configuration: Base Mount w/ Dryer; FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 33Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 8 kW | 8 kW | Frequency not stated · model Configuration: Tank Mount unspecified | Source · OEM_SOURCEPower: 8Retrieved 2026-10-05 |
| 8 kW | 8 kW | Frequency not stated · model Configuration: UltraPack unspecified | Source · OEM_SOURCEPower: 8Retrieved 2026-10-05 |
| 8 kW | 8 kW | Frequency not stated · model Configuration: Base Mount unspecified | Source · OEM_SOURCEPower: 8Retrieved 2026-10-05 |
| 8 kW | 8 kW | Frequency not stated · model Configuration: Base Mount w/ Dryer unspecified | Source · OEM_SOURCEPower: 8Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 60 dB(A) | 60 dB(A) | Frequency not stated · model Configuration: Tank Mount unspecified | Source · OEM_SOURCESound Level: 60Retrieved 2026-10-05 |
| 60 dB(A) | 60 dB(A) | Frequency not stated · model Configuration: UltraPack unspecified | Source · OEM_SOURCESound Level: 60Retrieved 2026-10-05 |
| 60 dB(A) | 60 dB(A) | Frequency not stated · model Configuration: Base Mount unspecified | Source · OEM_SOURCESound Level: 60Retrieved 2026-10-05 |
| 60 dB(A) | 60 dB(A) | Frequency not stated · model Configuration: Base Mount w/ Dryer unspecified | Source · OEM_SOURCESound Level: 60Retrieved 2026-10-05 |
Weight · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 868 lbs. | 393.7179 kg | Frequency not stated · model Configuration: Tank Mount unspecified | Source · OEM_SOURCEWeight: 868Retrieved 2026-10-05 |
| 945 lbs. | 428.6444 kg | Frequency not stated · model Configuration: UltraPack unspecified | Source · OEM_SOURCEWeight: 945Retrieved 2026-10-05 |
| 605 lbs. | 274.4232 kg | Frequency not stated · model Configuration: Base Mount unspecified | Source · OEM_SOURCEWeight: 605Retrieved 2026-10-05 |
| 682 lbs. | 309.3497 kg | Frequency not stated · model Configuration: Base Mount w/ Dryer unspecified | Source · OEM_SOURCEWeight: 682Retrieved 2026-10-05 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 150 psi | 10342.14 mbar | Frequency not stated · model the pressure "Capacity FAD 150 psi" is stated at (Configuration: Tank Mount; FAD 150 psi) free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 37Retrieved 2026-10-20 |
| 100 psi | 6894.76 mbar | Frequency not stated · model the pressure "Capacity FAD 100 psi" is stated at (Configuration: Tank Mount; FAD 100 psi) free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 45Retrieved 2026-10-20 |
| 125 psi | 8618.45 mbar | Frequency not stated · model the pressure "Capacity FAD 125 psi" is stated at (Configuration: Tank Mount; FAD 125 psi) free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 42Retrieved 2026-10-20 |
| 175 psi | 12065.83 mbar | Frequency not stated · model the pressure "Capacity FAD 175 psi" is stated at (Configuration: Tank Mount; FAD 175 psi) free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 33Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 4 | 0 |
|
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |