Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FS-Curtis NXD30: specifications, configurations, documents, sources, and gaps.

One model, connected records

FS-Curtis → FS-Curtis NX Series 15-185kW / 20-250HP → NXD30

Manufacturer model: NXD30 · OEM article / order number: Not collected · Equipment type: compressor

Technology: Rotary Screw

Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

11 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
201 CFM341.501 m3/hFrequency not stated · model
FAD 100 psi
free air delivery
Source · OEM_SOURCE
Capacity FAD 100 psi: 201
Retrieved 2026-10-05
201 CFM341.501 m3/hFrequency not stated · model
FAD 125 psi
free air delivery
Source · OEM_SOURCE
Capacity FAD 125 psi: 201
Retrieved 2026-10-05
171 CFM290.5307 m3/hFrequency not stated · model
FAD 150 psi
free air delivery
Source · OEM_SOURCE
Capacity FAD 150 psi: 171
Retrieved 2026-10-05
142 CFM241.2594 m3/hFrequency not stated · model
FAD 175 psi
free air delivery
Source · OEM_SOURCE
Capacity FAD 175 psi: 142
Retrieved 2026-10-05
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
30 kW30 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Power: 30
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
70 dB(A)70 dB(A)Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Sound Level: 70
Retrieved 2026-10-05
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1663 lbs.754.3235 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 1663
Retrieved 2026-10-05
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
125 psi8618.45 mbarFrequency not stated · model
the pressure "Capacity FAD 125 psi" is stated at (FAD 125 psi)
free air delivery
Source · OEM_SOURCE
Capacity FAD 125 psi: 201
Retrieved 2026-10-20
150 psi10342.14 mbarFrequency not stated · model
the pressure "Capacity FAD 150 psi" is stated at (FAD 150 psi)
free air delivery
Source · OEM_SOURCE
Capacity FAD 150 psi: 171
Retrieved 2026-10-20
100 psi6894.76 mbarFrequency not stated · model
the pressure "Capacity FAD 100 psi" is stated at (FAD 100 psi)
free air delivery
Source · OEM_SOURCE
Capacity FAD 100 psi: 201
Retrieved 2026-10-20
175 psi12065.83 mbarFrequency not stated · model
the pressure "Capacity FAD 175 psi" is stated at (FAD 175 psi)
free air delivery
Source · OEM_SOURCE
Capacity FAD 175 psi: 142
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation40
Drawings / dimensions00Not collected
Product / family literature30
Other / unclassified00Not collected