Data coverage & sources
The stored record for FS-Curtis NXHE260: specifications, configurations, documents, sources, and gaps.
One model, connected records
FS-Curtis → FS-Curtis NXHE Series Two-Stage 90-260kW / 125-350HP → NXHE260
Manufacturer model: NXHE260 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
14 stored observations · 13 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1891 CFM | 3212.828 m3/h | Frequency not stated · model FAD 100 psi free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 1891Retrieved 2026-10-05 |
| 1708 CFM | 2901.909 m3/h | Frequency not stated · model FAD 125 psi free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 1708Retrieved 2026-10-05 |
| 1535 CFM | 2607.98 m3/h | Frequency not stated · model FAD 150 psi free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 1535Retrieved 2026-10-05 |
| 1377 CFM | 2339.537 m3/h | Frequency not stated · model FAD 175 psi free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 1377Retrieved 2026-10-05 |
| 534 psi | 36818.02 mbar | Frequency not stated · model FAD Min. free air delivery | Source · OEM_SOURCECapacity FAD Min.: 534Retrieved 2026-10-05 |
| 1918 psi | 132241.5 mbar | Frequency not stated · model FAD Max. free air delivery | Source · OEM_SOURCECapacity FAD Max.: 1918Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 260 kW | 260 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPower: 260Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 85 dB(A) | 85 dB(A) | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCESound Level: 85Retrieved 2026-10-05 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 16799 lbs. | 7619.892 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 16799Retrieved 2026-10-05 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Range: Pressure Range · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 100 – 150 psi | 6894.76 mbar | Frequency not stated · range Conditions not stated unspecified | Source · OEM_SOURCE not a model rating Range: Pressure Range: 100 – 150Retrieved 2026-10-05 |
Reference working pressure · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 150 psi | 10342.14 mbar | Frequency not stated · model the pressure "Capacity FAD 150 psi" is stated at (FAD 150 psi) free air delivery | Source · OEM_SOURCECapacity FAD 150 psi: 1535Retrieved 2026-10-20 |
| 125 psi | 8618.45 mbar | Frequency not stated · model the pressure "Capacity FAD 125 psi" is stated at (FAD 125 psi) free air delivery | Source · OEM_SOURCECapacity FAD 125 psi: 1708Retrieved 2026-10-20 |
| 175 psi | 12065.83 mbar | Frequency not stated · model the pressure "Capacity FAD 175 psi" is stated at (FAD 175 psi) free air delivery | Source · OEM_SOURCECapacity FAD 175 psi: 1377Retrieved 2026-10-20 |
| 100 psi | 6894.76 mbar | Frequency not stated · model the pressure "Capacity FAD 100 psi" is stated at (FAD 100 psi) free air delivery | Source · OEM_SOURCECapacity FAD 100 psi: 1891Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 4 | 0 |
|
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |