Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Gast 1023-101Q-G279: specifications, configurations, documents, sources, and gaps.

One model, connected records

Gast → 1023-101Q-G279 → 1023-101Q-G279

Manufacturer model: 1023-101Q-G279 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Rotary Vane

Related applications: CNC Routing, Material Handling, Pick + Place, Vacuum Hold-Down
Related industries: Electronics, General Manufacturing, Printing, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

24 stored observations · 13 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
8.2 cfm13.9319 m3/h50 Hz · model
50 Hz; [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [cfm]: 8.2
Retrieved 2026-10-05
10 cfm16.9901 m3/h60 Hz · model
60 Hz; [cfm]
unspecified
Source · OEM_SOURCE
Open Flow [cfm]: 10
Retrieved 2026-10-05
232 lpm13.92 m3/h50 Hz · model
50 Hz; [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [lpm]: 232
Retrieved 2026-10-05
283 lpm16.98 m3/h60 Hz · model
60 Hz; [lpm]
unspecified
Source · OEM_SOURCE
Open Flow [lpm]: 283
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.75 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
HP: 0.75
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
<70 DBA70 dB(A)Frequency not stated · model
[DBA]
unspecified
Source · OEM_SOURCE
Sound Level [DBA]: <70
Retrieved 2026-10-05
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
47 lb21.3188 kgFrequency not stated · model
[lb]
unspecified
Source · OEM_SOURCE
Weight [lb]: 47
Retrieved 2026-10-05
21 kg21 kgFrequency not stated · model
[kg]
unspecified
Source · OEM_SOURCE
Weight [kg]: 21
Retrieved 2026-10-05
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
16.6 L x 8.5 W x 7.3 H L x 8.5 W x 7.3 H in— Frequency not stated · model
[in]
unspecified
Source · OEM_SOURCE
Dimensions [in]: 16.6 L x 8.5 W x 7.3 H
Retrieved 2026-10-05
421.6 L x 215.9 W x 185.4 H L x 215.9 W x 185.4 H mm— Frequency not stated · model
[mm]
unspecified
Source · OEM_SOURCE
Dimensions [mm]: 421.6 L x 215.9 W x 185.4 H
Retrieved 2026-10-05
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Amps · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
2.3-3.2/1.6 /1.6— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Amps: 2.3-3.2/1.6
Retrieved 2026-10-05
2.4-2.6/1.4 /1.4— 60 Hz · range
60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Amps: 2.4-2.6/1.4
Retrieved 2026-10-05
Coo · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
US — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
COO: US
Retrieved 2026-10-05
Flow at max. pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
7.5 cfm12.7426 m3/h50 Hz · model
50 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [cfm]: 7.5
Retrieved 2026-10-05
9 cfm15.2911 m3/h60 Hz · model
60 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [cfm]: 9
Retrieved 2026-10-05
212.4 lpm12.744 m3/h50 Hz · model
50 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [lpm]: 212.4
Retrieved 2026-10-05
254.9 lpm15.294 m3/h60 Hz · model
60 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [lpm]: 254.9
Retrieved 2026-10-05
Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
10 psi689.476 mbarFrequency not stated · model
[psi]
unspecified
Source · OEM_SOURCE
Max Pressure [psi]: 10
Retrieved 2026-10-05
0.69 Bar690 mbarFrequency not stated · model
[Bar]
unspecified
Source · OEM_SOURCE
Max Pressure [Bar]: 0.69
Retrieved 2026-10-05
Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
26 in hg26 inHgFrequency not stated · model
[in hg]
unspecified
Source · OEM_SOURCE
Max Vacuum [in hg]: 26
Retrieved 2026-10-05
Phase · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Three Phase — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Phase: Three Phase
Retrieved 2026-10-05
Regulatory · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
CE — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Regulatory: CE
Retrieved 2026-10-05
Voltage · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
208-220/440 /440— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Voltage: 208-220/440
Retrieved 2026-10-05
208-220/440 /440— 60 Hz · range
60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Voltage: 208-220/440
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals30
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected