Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Gast 5LCF-10-M551X: specifications, configurations, documents, sources, and gaps.

One model, connected records

Gast → 5LCF-10-M551X → 5LCF-10-M551X

Manufacturer model: 5LCF-10-M551X · OEM article / order number: Not collected · Equipment type: compressor

Technology: Reciprocating

Compare coverage across this family

Specifications and evidence

19 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.5 cfm9.3446 m3/h60 Hz · model
60 Hz; [cfm]
free air delivery
Source · OEM_SOURCE
Open Flow [cfm]: 5.5
Retrieved 2026-10-05
156 lpm9.36 m3/h60 Hz · model
60 Hz; [lpm]
free air delivery
Source · OEM_SOURCE
Open Flow [lpm]: 156
Retrieved 2026-10-05
Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
50 psi3447.38 mbarFrequency not stated · model
[psi]
unspecified
Source · OEM_SOURCE
Max Pressure [psi]: 50
Retrieved 2026-10-05
3.45 Bar3450 mbarFrequency not stated · model
[Bar]
unspecified
Source · OEM_SOURCE
Max Pressure [Bar]: 3.45
Retrieved 2026-10-05
Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.75 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
HP: 0.75
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
73-78 DBA73 dB(A)Frequency not stated · range
[DBA]
unspecified
Source · OEM_SOURCE
not a model rating
Sound Level [DBA]: 73-78
Retrieved 2026-10-05
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
40 lb18.1437 kgFrequency not stated · model
[lb]
unspecified
Source · OEM_SOURCE
Weight [lb]: 40
Retrieved 2026-10-05
18 kg18 kgFrequency not stated · model
[kg]
unspecified
Source · OEM_SOURCE
Weight [kg]: 18
Retrieved 2026-10-05
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
14.37 L x 12.28 W x 6.14 H L x 12.28 W x 6.14 H in— Frequency not stated · model
[in]
unspecified
Source · OEM_SOURCE
Dimensions [in]: 14.37 L x 12.28 W x 6.14 H
Retrieved 2026-10-05
365.0 L x 311.9 W x 156.0 H L x 311.9 W x 156.0 H mm— Frequency not stated · model
[mm]
unspecified
Source · OEM_SOURCE
Dimensions [mm]: 365.0 L x 311.9 W x 156.0 H
Retrieved 2026-10-05
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Amps · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
14.8/7.4 /7.4— 50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Amps: 14.8/7.4
Retrieved 2026-10-05
2 — 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Amps: 2
Retrieved 2026-10-05
Coo · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
US — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
COO: US
Retrieved 2026-10-05
Flow at max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4 cfm6.796 m3/h60 Hz · model
60 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [cfm]: 4
Retrieved 2026-10-05
113.3 lpm6.798 m3/h60 Hz · model
60 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [lpm]: 113.3
Retrieved 2026-10-05
Phase · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Single Phase — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Phase: Single Phase
Retrieved 2026-10-05
Regulatory · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
N/A — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Regulatory: N/A
Retrieved 2026-10-05
Voltage · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
100-110/220-240 /220-240— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Voltage: 100-110/220-240
Retrieved 2026-10-05
115/208-230 /208-230— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Voltage: 115/208-230
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10