Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Gast R5125Q-50: specifications, configurations, documents, sources, and gaps.

One model, connected records

Gast → R5125Q-50 → R5125Q-50

Manufacturer model: R5125Q-50 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

19 stored observations · 14 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
160 cfm271.8416 m3/h60 Hz · model
60 Hz; [cfm]
unspecified
Source · OEM_SOURCE
Open Flow [cfm]: 160
Retrieved 2026-10-05
4531 lpm271.86 m3/h60 Hz · model
60 Hz; [lpm]
unspecified
Source · OEM_SOURCE
Open Flow [lpm]: 4531
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
HP: 2
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
75 DBA75 dB(A)Frequency not stated · model
[DBA]
unspecified
Source · OEM_SOURCE
Sound Level [DBA]: 75
Retrieved 2026-10-05
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
77 lb34.9266 kgFrequency not stated · model
[lb]
unspecified
Source · OEM_SOURCE
Weight [lb]: 77
Retrieved 2026-10-05
35 kg35 kgFrequency not stated · model
[kg]
unspecified
Source · OEM_SOURCE
Weight [kg]: 35
Retrieved 2026-10-05
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
17.5 L x 13.56 W x 13.78 H L x 13.56 W x 13.78 H in— Frequency not stated · model
[in]
unspecified
Source · OEM_SOURCE
Dimensions [in]: 17.5 L x 13.56 W x 13.78 H
Retrieved 2026-10-05
444.5 L x 344.4 W x 350.0 H L x 344.4 W x 350.0 H mm— Frequency not stated · model
[mm]
unspecified
Source · OEM_SOURCE
Dimensions [mm]: 444.5 L x 344.4 W x 350.0 H
Retrieved 2026-10-05
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Amps · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
23/11.5 /11.5— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Amps: 23/11.5
Retrieved 2026-10-05
Coo · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
US — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
COO: US
Retrieved 2026-10-05
Flow at max. pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
105 cfm178.3961 m3/h60 Hz · model
60 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [cfm]: 105
Retrieved 2026-10-05
2973.3 lpm178.398 m3/h60 Hz · model
60 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [lpm]: 2973.3
Retrieved 2026-10-05
55 cfm93.4456 m3/h60 Hz · model
60 Hz; Vac [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [cfm]: 55
Retrieved 2026-10-05
1557.4 lpm93.444 m3/h60 Hz · model
60 Hz; Vac [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [lpm]: 1557.4
Retrieved 2026-10-05
Max. pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A psi— Frequency not stated · model
[psi]
unspecified
Source · OEM_SOURCE
Max Pressure [psi]: N/A
Retrieved 2026-10-05
Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A in hg— Frequency not stated · model
[in hg]
unspecified
Source · OEM_SOURCE
Max Vacuum [in hg]: N/A
Retrieved 2026-10-05
Phase · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Single Phase — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Phase: Single Phase
Retrieved 2026-10-05
Regulatory · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
N/A — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Regulatory: N/A
Retrieved 2026-10-05
Voltage · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
115/230 /230— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Voltage: 115/230
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected