Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Gast R6P355A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Gast → R6P355A → R6P355A

Manufacturer model: R6P355A · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 14 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
245 cfm416.2575 m3/h50 Hz · model
50 Hz; [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [cfm]: 245
Retrieved 2026-10-05
275 cfm467.2278 m3/h60 Hz · model
60 Hz; [cfm]
unspecified
Source · OEM_SOURCE
Open Flow [cfm]: 275
Retrieved 2026-10-05
6938 lpm416.28 m3/h50 Hz · model
50 Hz; [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [lpm]: 6938
Retrieved 2026-10-05
7787 lpm467.22 m3/h60 Hz · model
60 Hz; [lpm]
unspecified
Source · OEM_SOURCE
Open Flow [lpm]: 7787
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
6 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
HP: 6
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
79 DBA79 dB(A)Frequency not stated · model
[DBA]
unspecified
Source · OEM_SOURCE
Sound Level [DBA]: 79
Retrieved 2026-10-05
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
215 lb97.5223 kgFrequency not stated · model
[lb]
unspecified
Source · OEM_SOURCE
Weight [lb]: 215
Retrieved 2026-10-05
98 kg98 kgFrequency not stated · model
[kg]
unspecified
Source · OEM_SOURCE
Weight [kg]: 98
Retrieved 2026-10-05
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
16.59 L x 16.75 W x 18.15 H L x 16.75 W x 18.15 H in— Frequency not stated · model
[in]
unspecified
Source · OEM_SOURCE
Dimensions [in]: 16.59 L x 16.75 W x 18.15 H
Retrieved 2026-10-05
421.4 L x 425.5 W x 461.0 H L x 425.5 W x 461.0 H mm— Frequency not stated · model
[mm]
unspecified
Source · OEM_SOURCE
Dimensions [mm]: 421.4 L x 425.5 W x 461.0 H
Retrieved 2026-10-05
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Amps · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
14.4-13.4/7.2-6.8 /7.2-6.8— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Amps: 14.4-13.4/7.2-6.8
Retrieved 2026-10-05
13.0-12.0/.0 /.0— 60 Hz · range
60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Amps: 13.0-12.0/.0
Retrieved 2026-10-05
Coo · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
US — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
COO: US
Retrieved 2026-10-05
Flow at max. pressure · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
150 cfm254.8515 m3/h50 Hz · model
50 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [cfm]: 150
Retrieved 2026-10-05
220 cfm373.7822 m3/h60 Hz · model
60 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [cfm]: 220
Retrieved 2026-10-05
4247.5 lpm254.85 m3/h50 Hz · model
50 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [lpm]: 4247.5
Retrieved 2026-10-05
6229.7 lpm373.782 m3/h60 Hz · model
60 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [lpm]: 6229.7
Retrieved 2026-10-05
65 cfm110.4357 m3/h50 Hz · model
50 Hz; Vac [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Vac [cfm]: 65
Retrieved 2026-10-05
210 cfm356.7921 m3/h60 Hz · model
60 Hz; Vac [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [cfm]: 210
Retrieved 2026-10-05
1840.6 lpm110.436 m3/h50 Hz · model
50 Hz; Vac [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Vac [lpm]: 1840.6
Retrieved 2026-10-05
5946.5 lpm356.79 m3/h60 Hz · model
60 Hz; Vac [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [lpm]: 5946.5
Retrieved 2026-10-05
Max. pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A psi— Frequency not stated · model
[psi]
unspecified
Source · OEM_SOURCE
Max Pressure [psi]: N/A
Retrieved 2026-10-05
Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A in hg— Frequency not stated · model
[in hg]
unspecified
Source · OEM_SOURCE
Max Vacuum [in hg]: N/A
Retrieved 2026-10-05
Phase · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Three Phase — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Phase: Three Phase
Retrieved 2026-10-05
Regulatory · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
CSA — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Regulatory: CSA
Retrieved 2026-10-05
Voltage · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
190-220/380-415 /380-415— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Voltage: 190-220/380-415
Retrieved 2026-10-05
208-230/460 /460— 60 Hz · range
60 Hz
unspecified
Source · OEM_SOURCE
not a model rating
Voltage: 208-230/460
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified10